☠️
EXFILTRATING
DATA...
01010111 10110010 00101001 11000110 01101100 10011011 00010001 11100101 01000010 10101111
[ <-- BACK_TO_SEARCH ]
[ VENDOR STATS ]
CVSS: 6.6 CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 🐛 CWE-121
👁️
Common Weakness Enumeration - Identifies the specific category of software weakness or flaw.

CVE-2022-25785

CVE-2022-25785 Stack Buffer Overflow in Secomea
📅 PUBLISHED: 2022-05-04 00:00 UTC 🔄 UPDATED: 2026-08-14 04:47 UTC
[ PATCH UNDER REVIEW ↓ ] Remains UNDER REVIEW until an independent source confirms the fix
[ DEFENSE PATCH ↓ ]
💣 PoC: Public
👁️
Proof of Concept - Indicates if functional exploit code is publicly available, drastically increasing the risk of immediate attacks.
🎯 EPSS: 0.95%
👁️
0.95% probability
23.6× above the median CVE
Tier: ELEVATED
30-day exploitation window · FIRST.org · updated daily
🥷 MITRE: T1203
👁️
MITRE ATT&CK Tactic - Describes the strategy hackers use to execute this attack.
VULNERABLE: version not auto-detected — verify your deployed version locally
CVSS VECTOR BREAKDOWN 6.6
AV: L Attack Vector Local
AC: L Attack Complexity Low
PR: L Privileges Required Low
UI: N User Interaction None
S: U Scope Unchanged
C: H Confidentiality High
I: H Integrity High
A: H Availability High
6.6
THREAT LEVEL
■ tracking this CVE ✓ independent patch confirmation ⧗ same-origin mirror (GHSA) ⚠ active exploitation verification policy →

Executive Summary

CVE-2022-25785 is a stack-based buffer overflow vulnerability in Secomea SiteManager, an industrial remote access gateway product. The flaw permits a logged-in or local user to achieve arbitrary code execution on the underlying device — a critical concern given SiteManager's role in bridging OT/ICS networks to corporate IT. All versions of SiteManager prior to 9.7 are affected, and the CVSS score of 6.6 reflects the local/low-complexity nature of the attack. While no public exploit code is currently available and the vulnerability is not listed on CISA's Known Exploited Vulnerabilities (KEV) catalog, the severity of arbitrary code execution on an industrial gateway warrants immediate patching and monitoring, particularly for systems exposed to the internet.

⚡ AUTOMATE YOUR CVE INTELLIGENCE

This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.

›Patch confidence — UNVERIFIED to CONFIRMED, cross-referenced NVD + RHSA + Debian
›Exploit & PoC — poc_status, poc_url, has_exploit. Not in NVD.
›Shodan dorks — ready-made queries to find exposed vulnerable systems
›Detection rules — YARA · Wazuh · Elastic (all plans) · Sigma (Pro)
›pending_fields — know exactly which of 7 fields NVD hasn't processed yet
›Free backfill — data incomplete when you paid? Re-check within 30 days = 0 credits
PAYG €0.08/lookup Standard €19/mo (was €29) · 5k credits Pro €65/mo (was €99) · 20k credits FOUNDING PRICE · LOCKED FOR LIFE · ENDS 31 DEC 2026
[ FROM €19/MO ]
Free sandbox key available
No signup required

Technical Analysis

The vulnerability is classified as a stack-based buffer overflow (CWE-121), a memory corruption flaw in which data written to a fixed-size stack buffer exceeds its allocated boundaries. When a crafted input of excessive length is supplied to a code path in SiteManager that copies data into a stack-allocated array without proper bounds checking, the overflow overwrites adjacent memory on the call stack — including the saved return address and possibly other critical control structures.

The NVD description specifies that the attack requires a "logged-in or local user" — indicating the attacker must already possess some level of access to the device, either via an authenticated session (e.g., through the web management interface, SSH, or a serial console) or physical/local access. This places the attack surface on authenticated functionality rather than unauthenticated network-facing endpoints. The exact vulnerable function is not disclosed in the available data; insufficient technical detail is available to identify the specific code path, parameter, or request type that triggers the overflow.

The attack mechanism follows the classic stack overflow pattern:

  1. Input supply: An attacker submits an overly long input value through an authenticated interface or local command.
  2. Overflow trigger: The input is copied into a stack buffer using an unsafe operation (e.g., unbounded strcpy, sprintf, or similar) without length validation.
  3. Control flow hijack: The overflow overwrites the saved return address (EIP/RIP) on the stack, redirecting execution to attacker-controlled data (typically shellcode placed within the overflowing buffer or in a known location).
  4. Arbitrary execution: The attacker gains code execution in the context of the SiteManager process, which likely runs with elevated privileges on the gateway device.

Given that SiteManager serves as an industrial remote access gateway — often positioned between corporate networks and OT/SCADA environments — successful exploitation could allow an attacker to pivot into the ICS network, manipulate industrial processes, or exfiltrate sensitive operational data.


Exploitation Scenarios

Attack chain description — No public PoC or exploit code is currently available; the attack chain is inferred from the vulnerability class and the NVD description. The attack requires authenticated or local access.

Step 1 — Reconnaissance/Target Identification: An attacker identifies a Secomea SiteManager appliance, likely through internet-exposed management interfaces (e.g., the web-based configuration panel). Shodan/Censys queries such as title:"SiteManager" can locate exposed devices. The attacker determines (a) the device is running a version prior to 9.7, and (b) obtains valid credentials — either through credential stuffing, weak-password guessing, phishing an administrator, or by gaining local access to the device.

Step 2 — Flaw Trigger: The attacker authenticates to the SiteManager interface and navigates to a functionality that processes raw input destined for a stack buffer. Because the specific vulnerable endpoint is undisclosed, the attacker would need to fuzz or reverse-engineer the device firmware to locate the overflow trigger. In a generic stack-overflow scenario, the attacker submits a payload with a large prefix of innocuous data, followed by a carefully crafted return-address overwrite (e.g., "A"*offset + address-of-shellcode).

Step 3 — Payload/Execution: At the vulnerability-class level, the payload is typically a multi-stage approach: (a) a primary buffer containing shellcode (e.g., a bind shell, reverse shell, or command-execution stub), (b) the overflow data that overwrites the saved return address to point into the shellcode, and (c) possible NOP sled for reliability. Because the device runs an embedded operating system, the shellcode would need to be architecture-specific (e.g., ARM, MIPS, or x86 depending on the hardware platform). On successful overflow, the process jumps to the shellcode and executes it in the context of the SiteManager service — potentially with root/system privileges.

Step 4 — Post-Exploitation Impact: Once arbitrary code execution is achieved, the attacker can: (a) extract credentials and configuration files from the device, (b) establish persistence (e.g., modified firmware, cron jobs, or a hidden backdoor), (c) use the SiteManager as a pivot point to reach downstream OT/SCADA assets (PLCs, HMIs, RTUs) that the gateway is configured to route to, and (d) potentially disrupt industrial operations by manipulating gateway settings or falsifying alarms.

Key constraints: The attack is not remotely exploitable without authentication — a mitigating factor that explains the relatively moderate CVSS base score of 6.6 despite the critical nature of the impact (arbitrary code execution). However, "logged-in" users could include low-privileged accounts (e.g., support personnel or read-only users), depending on the privilege model of SiteManager. If a low-privilege account can trigger the overflow, the vulnerability becomes a privilege escalation vector as well.


Impact Assessment

CVSS Interpretation: With a base score of 6.6 and vector characteristics reflecting Local (AV:L), Low complexity (AC:L), Low privileges required (PR:L), No user interaction (UI:N), and Unchanged scope (S:U), the vulnerability offers a high confidentiality, integrity, and availability impact (C:H/I:H/A:H) — but only from a local/authenticated position. This places it in the Medium severity band but with high-severity consequences on successful exploitation.

Business Impact:

  • Confidentiality breach: An attacker who achieves code execution can read all device-stored secrets — VPN credentials, site-to-site tunnel keys, remote-access user lists, and network topology information for connected OT assets.
  • Integrity compromise: The attacker can modify configuration files, alter access-control rules, or inject malicious firmware components — undermining the trust boundary of the remote access solution.
  • Availability loss: Malicious code could crash the SiteManager process, drop the gateway's connections to remote sites, or brick the device entirely — directly impacting operational continuity for any industrial facility relying on remote access.
  • Compliance/reputational risk: For organizations in critical infrastructure, utilities, or manufacturing, a compromised remote access gateway may trigger regulatory reporting (e.g., NERC CIP, IEC 62443) and erode customer confidence.

Blast radius: The affected population includes all Secomea SiteManager deployments running versions prior to 9.7 — spanning industrial, energy, and utility sectors where remote access to field devices is necessary. The blast radius extends beyond the gateway itself: a compromised SiteManager provides a foothold into the segmented OT network, exposing potentially hundreds of downstream industrial assets to lateral movement and manipulation.

Threat landscape: The EPSS score of 0.00946 (58th percentile) indicates a relatively low probability of exploitation in the wild at present — consistent with the absence of public PoC and the lack of inclusion on CISA's KEV list. However, the vulnerability class (stack overflow executed as root on an OT gateway) is a historically attractive target for APT groups focused on industrial espionage and sabotage. Monitoring for new exploit disclosures is critical.


Detection Guidance

Sigma Rule

title: Secomea SiteManager Stack Buffer Overflow Attempt
id: 8f1c7e2a-9d4e-4b6a-8c1d-3f5a2e6b7c8d
status: experimental
description: Detects anomalous oversized input patterns sent to Secomea SiteManager interfaces, potentially indicating stack buffer overflow exploitation (CVE-2022-25785).
references:
    - https://nvd.nist.gov/vuln/detail/CVE-2022-25785
author: Valtersit Threat Intelligence
date: 2025/01/15
logsource:
    category: application
    product: secomea_sitemanager
detection:
    selection_large_input:
        cs_length:
            - '> 4096'  # size threshold, adjust based on legitimate max input length
    selection_hex_pattern:
        cs_uri_query|contains:
            - '%41%41%41'  # repeated 'A' characters indicating overflow padding
            - '%90%90%90'  # NOP sled patterns
    selection_response:
        cs_response_code:
            - '500'
            - '502'
    condition: selection_large_input and selection_hex_pattern
    or selection_large_input and selection_response
level: high
tags:
    - attack.t1203
    - cve.2022.25785

YARA Rule

rule Secomea_SiteManager_StackOverflow_Exploit_CVE_2022_25785 {
    meta:
        author = "Valtersit Threat Intelligence"
        description = "Detects exploit payload patterns targeting the stack buffer overflow in Secomea SiteManager (CVE-2022-25785)"
        reference = "https://nvd.nist.gov/vuln/detail/CVE-2022-25785"
        date = "2025-01-15"
        severity = "high"
    strings:
        $nop_sled = { 90 90 90 90 90 90 90 90 90 90 }
        $shell_code_marker = { 31 c0 50 68 2f 2f 73 68 }  // /bin/sh execve stub (x86)
        $long_ascii_a = /A{64,}/
        $long_ascii_b = /B{64,}/
        $ret_address = { 0? 0? 0? 0? }  // generic address block
    condition:
        (uint16(0) == 0x7B22 or uint32(0) == 0x504448) or
        ($nop_sled at any and $shell_code_marker at any) or
        ($long_ascii_a and $long_ascii_b and $ret_address)
}

Note: This YARA rule is designed to detect generic shellcode/padding patterns that would be embedded in crafted inputs or memory dumps of a compromised SiteManager. It is intentionally broad; tune the condition based on your environment's legitimate traffic characteristics.

Suricata IDS Rule

alert http any any -> $SITEMANAGER_IP any (msg:"CVE-2022-25785 Secomea SiteManager Stack Buffer Overflow Attempt"; flow:established,to_server; content:"POST"; http_method; content:"/"; http_uri; pcre:"/(?:%41){16,}/i"; pcre:"/(?:%90){16,}/i"; classtype:attempted-admin; sid:20250115; rev:1; reference:cve,2022-25785;)

Note: This rule detects HTTP requests containing a high density of repeated %41 (A) and %90 (NOP) URL-encoded characters — indicative of overflow padding and NOP sleds. Adjust the threshold ({16,}) based on the maximum legitimate input length of the SiteManager web interface.

Elastic Detection

// EQL query to detect oversized HTTP requests to SiteManager
sequence by source.ip
  [network where process.name == "nginx" and
      event.action == "accepted" and
      network.protocol == "http"]
  [http where event.action == "request" and
      url.path != "*" and
      http.request.bytes > 5000]
  [http where event.action == "request" and
      url.query contains "AAAA" or
      url.query contains "%41%41%41"]

Note: This EQL rule looks for outbound request sequences with unusually large request sizes and URL-encoded padding patterns. Tune thresholds to match your legitimate traffic baselines.

Splunk SPL Query

index=web sourcetype=access_combined site="*sitemanager*"
| where req_bytes > 5000
| regex url="(?i)(?:%41){20,}|(?:AAAA){20,}|(?:%90){20,}|(?:NOP){20,}"
| eval attack = "CVE-2022-25785_stack_overflow_suspect"
| table _time, src_ip, src_port, dest_ip, url, req_bytes, status
| sort - _time

Note: Adjust the index, sourcetype, and field names to match your web proxy/access log schema.

Wazuh OSSEC Rule

<group name="secomea,">
  <rule id="202515" level="12">
    <decoded>web-access-log</decoded>
    <match>sitemanager|SiteManager</match>
    <regex>(?:%41){16,}|(?:AAAA){16,}</regex>
    <description>Potential stack buffer overflow exploitation attempt against Secomea SiteManager (CVE-2022-25785)</description>
    <mitre>
      <id>T1203</id>
    </mitre>
    <group>attack.t1203,</group>
    <options>no_full_log</options>
  </rule>
</group>

Note: This rule triggers on web access logs that reference SiteManager URLs and contain long repetitive A / %41 sequences.


Mitigation & Patch Guidance

Patch status: The CNA claims a patch exists in version 9.7; this claim is not independently confirmed (confidence 2/4). Organizations should validate the fix by contacting Secomea support or reviewing the official release notes.

1) Immediate mitigations:

  • Restrict access to the SiteManager management interface: Ensure that only authorized personnel — from trusted IP ranges — can reach the web management console, SSH, or serial console. Use network ACLs and firewall rules to block untrusted sources.
  • Enforce strong authentication: Implement multi-factor authentication (MFA) for all SiteManager accounts. Change default passwords immediately.
  • Disable unnecessary services: If local shell access or debugging interfaces are not required, disable them to reduce the local-attack surface.
  • Segment the network: Isolate the SiteManager device in a DMZ with strict egress rules, preventing it from reaching unrelated corporate resources.

2) Patch/Upgrade steps:

  • Review the Secomea advisory (referenced below) and verify that version 9.7 or later contains the fix for CVE-2022-25785.
  • Plan a maintenance window to upgrade affected SiteManager installations to version 9.7 or newer, following the official upgrade procedure.
  • Verify post-upgrade functionality: confirm that remote access tunnels, VPN connections, and management access all function correctly after the upgrade.
  • If upgrading is not immediately possible, monitor all login activity and restrict the user base to the minimum number of trusted accounts.

3) Long-term hardening:

  • Maintain a vulnerability management program that tracks CVEs for all OT/ICS network infrastructure products.
  • Subscribe to Secomea's security advisories and patch notification feeds.
  • Conduct regular penetration testing of remote access gateways to identify and remediate weaknesses in authentication and input validation.
  • Implement centralised logging for SiteManager and integrate with your SIEM/SOC for ongoing monitoring.
  • Follow vendor security best practices and reference frameworks such as IEC 62443 for industrial network segmentation and remote-access hardening.

References

  1. NVD Entry: https://nvd.nist.gov/vuln/detail/CVE-2022-25785
  2. Secomea Product Security Page (vendor advisory): https://www.secomea.com/support/vulnerability-advisories/ — Actively validate patch claim and retrieve specific advisory for version 9.7.
  3. CISA Known Exploited Vulnerabilities Catalog: https://www.cisa.gov/known-exploited-vulnerabilities-catalog — CVE-2022-25785 is NOT listed (verified as of writing).
  4. CWE-121 (Stack-based Buffer Overflow): https://cwe.mitre.org/data/definitions/121.html — Reference for vulnerability class understanding.
  5. EPSS Data: https://www.first.org/epss/ — EPSS score 0.00946 (58th percentile).

Threat actor / exploit-in-the-wild evidence: As of the report date, there is no publicly available evidence of active exploitation, no PoC/exploit code releases, and no CISA KEV listing for CVE-2022-25785. The vulnerability remains a latent risk requiring proactive remediation.

👁️ SHODAN DORKS (THREAT HUNTING)

What is this? Security researchers use these exact search queries on Shodan.io (a search engine for internet-connected devices) to find vulnerable systems globally. You can copy these dorks to see if your organization's IP space is exposed.

title:"SiteManager"
product:"Secomnea SiteManager"
"Secomnea" "SiteManager"

💣 PoC CODE AVAILABLE

Exploit code for this CVE is tracked in our database. Access poc_code via API Pro.

[ API_PRO ] →
◈ SOURCE Analysis & enrichment: valtersit.com/cve/CVE-2022-25785/ · CVE data: NVD/MITRE (public domain) · © 2026 ValtersIT Hub
>_ SYSTEM_CORE: INTEL_ACTIVE
90% TEAM-CURATED // 10% AUTOMATED INGESTION.
ALL PATCH REFERENCES AND VERSION DATA SOURCED FROM NVD + OSV OFFICIAL REGISTRIES.