CVE-2023-43849
Executive Summary
CVE-2023-43849 is a critical vulnerability in the Aten PE6208 PDU (Power Distribution Unit) firmware upgrade function. The flaw allows remote authenticated users to submit arbitrary firmware images via HTTP POST requests due to incorrect access control. This can lead to Denial of Service (DoS) or Remote Code Execution (RCE) on the device. The vulnerability affects firmware versions 2.3.228 and 2.4.232. No official patch has been released, and no public proof-of-concept (PoC) or exploit code is currently available. The EPSS score is 0.0%, indicating low exploitation activity in the wild, but the potential impact is severe for organizations using this device in critical infrastructure.
This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.
No signup required
Supply Chain & Package Security
This vulnerability is not related to NPM, PyPI, Go, or Ruby packages. It affects a hardware device (Aten PE6208 PDU) and its embedded firmware. Supply chain risk is limited to the device itself and its firmware update mechanism.
CVSS Breakdown & Threat Level
The CVSS score is listed as 0.0 in the NVD data, but this is likely a placeholder. Based on the description, a reasonable CVSS v3.1 vector would be:
- Attack Vector (AV): Network (N)
- Attack Complexity (AC): Low (L)
- Privileges Required (PR): Low (L) – requires authentication
- User Interaction (UI): None (N)
- Scope (S): Unchanged (U)
- Confidentiality (C): High (H) – RCE can lead to data exfiltration
- Integrity (I): High (H) – firmware modification
- Availability (A): High (H) – DoS possible
Estimated CVSS Score: 8.8 (High)
Threat Level: High. The vulnerability allows authenticated users to upload malicious firmware, potentially leading to full device compromise. Since the device is a PDU, it could be used as a pivot point in a network or to disrupt power distribution.
Deep Dive & Mechanics
The Aten PE6208 is a network-managed PDU that provides remote power monitoring and control. The web interface includes a firmware upgrade function intended for authorized administrators to update the device's firmware. The vulnerability lies in the access control mechanism for this function.
Root Cause: The firmware upgrade endpoint does not properly verify that the authenticated user has administrative privileges. Any authenticated user (even with low privileges) can send an HTTP POST request to the firmware upgrade endpoint with a crafted firmware image.
Attack Flow:
- Attacker gains valid credentials (e.g., via phishing, default credentials, or brute force).
- Attacker crafts a malicious firmware image containing arbitrary code (e.g., a reverse shell or backdoor).
- Attacker sends an HTTP POST request to the firmware upgrade endpoint (e.g.,
/cgi-bin/upgrade.cgior similar) with the malicious image. - The device accepts the image and begins the upgrade process.
- The malicious firmware is installed, giving the attacker full control over the PDU.
Impact:
- Denial of Service (DoS): Uploading a corrupted or incompatible firmware image can brick the device.
- Remote Code Execution (RCE): A carefully crafted firmware image can execute arbitrary commands on the device's operating system.
- Network Pivot: The compromised PDU can be used to launch attacks against other devices on the same network segment.
Vulnerable vs. Patched Code
Since no patch is available, we can only analyze the vulnerable code pattern. The vulnerable endpoint likely lacks a privilege check.
Vulnerable Code (Conceptual):
# Example of vulnerable Python-like pseudocode
@app.route('/firmware_upgrade', methods=['POST'])
def firmware_upgrade():
# No privilege check
firmware = request.files['firmware']
# Process and install firmware
install_firmware(firmware)
return "Upgrade initiated"
Patched Code (Conceptual):
# Example of patched Python-like pseudocode
@app.route('/firmware_upgrade', methods=['POST'])
def firmware_upgrade():
# Check if user is admin
if not current_user.is_admin:
return "Unauthorized", 403
firmware = request.files['firmware']
# Additional validation: check firmware signature, hash, etc.
if not verify_firmware_signature(firmware):
return "Invalid firmware", 400
install_firmware(firmware)
return "Upgrade initiated"
Exploitation & Lab Setup
Red Team
Prerequisites:
- Valid credentials for the Aten PE6208 web interface (e.g.,
admin:adminor obtained via other means). - Network access to the device's web interface (typically port 80 or 443).
Exploitation Steps:
- Reconnaissance: Identify the firmware upgrade endpoint. This can be done by inspecting the web interface's HTML forms or using a proxy like Burp Suite.
- Craft Malicious Firmware: Create a modified firmware image that includes a backdoor. This requires reverse engineering the original firmware (e.g., using
binwalkto extract the filesystem, then modifying startup scripts to include a reverse shell). - Upload Firmware: Send an HTTP POST request to the upgrade endpoint with the malicious firmware.
curl -X POST -F "firmware=@malicious_firmware.bin" -u "username:password" http://<target_ip>/cgi-bin/upgrade.cgi - Trigger Execution: The device will reboot and run the malicious firmware. The backdoor will execute, providing remote access (e.g., a reverse shell to the attacker's listener).
Alternative DoS Attack:
- Upload a corrupted firmware image to brick the device.
curl -X POST -F "firmware=@corrupted.bin" -u "username:password" http://<target_ip>/cgi-bin/upgrade.cgi
Blue Team
Detection:
- Monitor for unusual HTTP POST requests to firmware upgrade endpoints.
- Alert on multiple failed login attempts followed by a successful login and firmware upload.
- Use network monitoring to detect large file uploads to the device.
Prevention:
- Restrict access to the web interface to trusted IP addresses only.
- Enforce strong, unique passwords and multi-factor authentication.
- Disable the firmware upgrade function if not needed.
- Implement network segmentation to isolate PDUs from critical systems.
Response:
- If a malicious firmware upload is detected, immediately disconnect the device from the network.
- Reflash the device with a known good firmware image (if possible) or replace the device.
- Investigate the source of the credentials used.
Indicators of Compromise (IOCs)
- Network IOCs:
- HTTP POST requests to
/cgi-bin/upgrade.cgior similar endpoints. - Large file uploads (firmware images) to the device.
- Outbound connections from the PDU to unknown IP addresses (reverse shell).
- HTTP POST requests to
- Host IOCs:
- Unexpected firmware version installed.
- Modified startup scripts or binaries on the device.
- New listening ports on the PDU (e.g., a backdoor shell).
- Log IOCs:
- Successful login from an unusual IP address followed by a firmware upgrade action.
- Error logs indicating failed firmware validation (if any).
Detection Engineering
YARA Rule
rule CVE_2023_43849_Aten_PE6208_Firmware_Upload {
meta:
description = "Detects HTTP POST requests to Aten PE6208 firmware upgrade endpoint"
author = "Valters IT"
date = "2025-04-10"
reference = "CVE-2023-43849"
strings:
$upgrade_endpoint = "/cgi-bin/upgrade.cgi"
$firmware_field = "firmware"
$http_post = "POST"
condition:
$http_post and $upgrade_endpoint and $firmware_field
}
Sigma Rule
title: CVE-2023-43849 - Aten PE6208 Firmware Upgrade Abuse
id: 7a8b9c0d-1e2f-3a4b-5c6d-7e8f9a0b1c2d
status: experimental
description: Detects HTTP POST requests to the Aten PE6208 firmware upgrade endpoint by non-admin users.
author: Valters IT
date: 2025-04-10
references:
- https://nvd.nist.gov/vuln/detail/CVE-2023-43849
logsource:
category: webserver
product: apache
service: access_log
detection:
selection:
cs-method: 'POST'
cs-uri-stem: '/cgi-bin/upgrade.cgi'
condition: selection
falsepositives:
- Legitimate firmware upgrades by authorized administrators
level: high
Suricata Rule
alert http $HOME_NET any -> $EXTERNAL_NET any (msg:"CVE-2023-43849 - Aten PE6208 Firmware Upgrade Attempt"; flow:to_server; content:"POST"; http_method; content:"/cgi-bin/upgrade.cgi"; http_uri; content:"firmware"; http_client_body; classtype:attempted-admin; sid:1000001; rev:1;)
Remediation & Mitigation
Immediate Actions:
- Restrict Access: Use firewall rules to limit access to the PDU's web interface to only trusted administrative IP addresses.
- Change Default Credentials: Ensure all default passwords are changed to strong, unique passwords.
- Disable Unused Features: If the firmware upgrade function is not required, disable it via the device's configuration.
Long-Term Actions:
- Vendor Contact: Reach out to Aten for an official patch or firmware update.
- Network Segmentation: Place PDUs on a separate management VLAN with strict access controls.
- Monitoring: Implement logging and monitoring for all administrative actions on the PDU.
- Alternative Solutions: Consider replacing the device with a patched or more secure alternative if no patch is forthcoming.
Workaround:
- If the firmware upgrade function cannot be disabled, implement a reverse proxy that requires additional authentication before forwarding requests to the upgrade endpoint.
Valters IT
DevSecOps & Cyber Threat Intelligence Expert
What is this? Security researchers use these exact search queries on Shodan.io (a search engine for internet-connected devices) to find vulnerable systems globally. You can copy these dorks to see if your organization's IP space is exposed.
💣 PoC CODE AVAILABLE
Exploit code for this CVE is tracked in our database.
Access poc_code via API Pro.