EXFILTRATING
DATA...
01010111 10110010 00101001 11000110 01101100 10011011 00010001 11100101 01000010 10101111
[ <-- BACK_TO_SEARCH ]
[ VENDOR STATS ]
CVSS: 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 🐛 CWE-312
👁️
Common Weakness Enumeration - Identifies the specific category of software weakness or flaw.

CVE-2024-36081

CVE-2024-36081 Security Advisory in Westermo
📅 PUBLISHED: 2024-05-19 20:05 UTC 🔄 UPDATED: 2026-08-12 09:04 UTC
[ ZERO-DAY / UNPATCHED ] [ DEFENSE PATCH ↓ ]
💣 PoC: Public
👁️
Proof of Concept - Indicates if functional exploit code is publicly available, drastically increasing the risk of immediate attacks.
🎯 EPSS: 0.17%
👁️
0.17% probability
4.3× above the median CVE
Tier: ELEVATED
30-day exploitation window · FIRST.org · updated daily
🥷 MITRE: T1190
👁️
MITRE ATT&CK Tactic - Describes the strategy hackers use to execute this attack.
VULNERABLE: UNKNOWN / CHECK VENDOR
CVSS VECTOR BREAKDOWN 9.8
AV: N Attack Vector Network
AC: L Attack Complexity Low
PR: N Privileges Required None
UI: N User Interaction None
S: U Scope Unchanged
C: H Confidentiality High
I: H Integrity High
A: H Availability High
9.8
THREAT LEVEL
■ tracking this CVE ✓ independent patch confirmation ⧗ same-origin mirror (GHSA) ⚠ active exploitation verification policy →

Executive Summary

CVE-2024-36081 is a critical vulnerability affecting Westermo EDW-100 serial-to-Ethernet converters. The flaw allows an unauthenticated remote attacker to download the device’s configuration file, which contains credentials in cleartext. With a CVSS score of 9.8, this vulnerability poses a severe risk to operational technology (OT) environments, as it can lead to full device compromise and lateral movement within industrial networks. The vendor has not released a patch, and the device is explicitly not designed for edge deployment, yet many remain exposed.

⚡ AUTOMATE YOUR CVE INTELLIGENCE

This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.

›Patch confidence — UNVERIFIED to CONFIRMED, cross-referenced NVD + RHSA + Debian
›Exploit & PoC — poc_status, poc_url, has_exploit. Not in NVD.
›Shodan dorks — ready-made queries to find exposed vulnerable systems
›Detection rules — YARA · Wazuh · Elastic (all plans) · Sigma (Pro)
›pending_fields — know exactly which of 7 fields NVD hasn't processed yet
›Free backfill — data incomplete when you paid? Re-check within 30 days = 0 credits
PAYG €0.08/lookup Standard €19/mo (was €29) · 5k credits Pro €65/mo (was €99) · 20k credits FOUNDING PRICE · LOCKED FOR LIFE · ENDS 31 DEC 2026
[ FROM €19/MO ]
Free sandbox key available
No signup required

CVSS Breakdown & Threat Level

  • CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
  • Base Score: 9.8 (Critical)
  • Attack Vector: Network
  • Attack Complexity: Low
  • Privileges Required: None
  • User Interaction: None
  • Scope: Unchanged
  • Confidentiality Impact: High
  • Integrity Impact: High
  • Availability Impact: High

The threat level is critical due to the lack of authentication required, the cleartext storage of credentials, and the potential for full device takeover. The EPSS score of 0.0% indicates low exploitation likelihood currently, but the public disclosure of the vulnerability increases risk.

Deep Dive & Mechanics

The Westermo EDW-100 is a serial-to-Ethernet converter used to connect legacy serial devices (e.g., PLCs, RTUs) to IP networks. The vulnerability resides in the device’s web interface or management API, which exposes the configuration file without authentication. An attacker can send a simple HTTP GET request to retrieve the configuration, which includes cleartext passwords for device administration and potentially for connected serial devices.

The root cause is the lack of access control on the configuration endpoint and the insecure storage of credentials. The device does not enforce authentication before serving sensitive data, violating fundamental security principles. This is particularly dangerous in OT environments where such devices may bridge critical control networks.

Vulnerable vs. Patched Code

No patch is available. The vulnerable code is the web server implementation that serves the configuration file without authentication. A patched version would require:

  • Implementing authentication (e.g., HTTP Basic Auth or session-based) for the configuration endpoint.
  • Encrypting stored passwords using a strong hashing algorithm (e.g., bcrypt) instead of cleartext.
  • Restricting access to the configuration endpoint to authorized IP addresses or VLANs.

Since no patch exists, the only mitigation is network segmentation and access controls.

Exploitation & Lab Setup

Red Team

Exploitation Steps:

  1. Identify Westermo EDW-100 devices on the network using Shodan or Nmap.
  2. Send an HTTP GET request to the configuration endpoint:
    curl http://<target-ip>/config.bin -o config.bin
    
    or
    wget http://<target-ip>/config.bin
    
  3. Extract cleartext passwords from the downloaded file (e.g., using strings or a hex editor):
    strings config.bin | grep -i password
    
  4. Use the extracted credentials to log into the device’s web interface or SSH service.
  5. Pivot to connected serial devices or the internal OT network.

Lab Setup:

  • Use a virtualized Westermo EDW-100 firmware image (if available) or a real device in an isolated lab.
  • Attacker machine: Kali Linux with curl, wget, and strings.
  • Network: Isolated VLAN with the device and attacker on the same subnet.

Blue Team

Detection & Response:

  • Monitor for HTTP GET requests to /config.bin or similar paths from unauthorized IPs.
  • Alert on cleartext password strings in network traffic (e.g., password=, passwd=).
  • Use network segmentation to isolate EDW-100 devices from untrusted networks.
  • Implement strict firewall rules to allow only necessary traffic (e.g., specific source IPs for management).

Indicators of Compromise (IOCs)

  • Network IOCs:
    • HTTP GET requests to /config.bin or /config on port 80/443.
    • Outbound connections from the device to unknown IPs after exploitation.
    • Cleartext password strings in HTTP responses (e.g., admin:password).
  • File IOCs:
    • Configuration file (config.bin) containing cleartext credentials.
    • Unauthorized SSH or web sessions from unknown IPs.
  • System IOCs:
    • Unusual device reboots or configuration changes.
    • New user accounts or modified passwords.

Detection Engineering

YARA Rule

rule CVE_2024_36081_Westermo_Config_Leak {
    meta:
        description = "Detects Westermo EDW-100 configuration file containing cleartext passwords"
        author = "Valters IT"
        date = "2024-05-10"
        reference = "CVE-2024-36081"
    strings:
        $password = /password\s*=\s*[^\s]+/ nocase
        $config_header = "EDW-100" nocase
        $cleartext = /passwd|secret|admin/ nocase
    condition:
        $config_header and ($password or $cleartext)
}

Sigma Rule

title: Westermo EDW-100 Configuration File Download Attempt
id: 8a9b3c4d-5e6f-7a8b-9c0d-1e2f3a4b5c6d
status: experimental
description: Detects HTTP GET requests to Westermo EDW-100 configuration endpoint
author: Valters IT
date: 2024-05-10
references:
    - https://nvd.nist.gov/vuln/detail/CVE-2024-36081
logsource:
    category: webserver
    product: apache
    service: http
detection:
    selection:
        cs-method: 'GET'
        cs-uri-stem:
            - '/config.bin'
            - '/config'
    condition: selection
falsepositives:
    - Legitimate administrative access from authorized IPs
level: high
tags:
    - attack.initial-access
    - attack.t1190

Suricata Rule

alert http any any -> any any (msg:"CVE-2024-36081 Westermo EDW-100 Config Download Attempt"; flow:to_server; content:"GET"; http_method; content:"/config.bin"; http_uri; classtype:attempted-recon; sid:1000001; rev:1;)

Remediation & Mitigation

  • Immediate Actions:
    • Isolate all Westermo EDW-100 devices behind firewalls and VPNs.
    • Restrict management access to trusted IPs only.
    • Disable unused web interfaces or change default ports.
  • Long-term:
    • Replace EDW-100 devices with patched or alternative products.
    • Implement network segmentation (e.g., OT-specific VLANs).
    • Use encrypted protocols (HTTPS, SSH) for device management.
  • Monitoring:
    • Deploy the provided YARA, Sigma, and Suricata rules.
    • Monitor for unauthorized configuration downloads.
    • Conduct regular vulnerability scans.

Valters IT
DevSecOps & Cyber Threat Intelligence Expert

👁️ SHODAN DORKS (THREAT HUNTING)

What is this? Security researchers use these exact search queries on Shodan.io (a search engine for internet-connected devices) to find vulnerable systems globally. You can copy these dorks to see if your organization's IP space is exposed.

Westermo EDW-100
EDW-100 configuration

💣 PoC CODE AVAILABLE

Exploit code for this CVE is tracked in our database. Access poc_code via API Pro.

[ API_PRO ] →
◈ SOURCE Analysis & enrichment: valtersit.com/cve/CVE-2024-36081/ · CVE data: NVD/MITRE (public domain) · © 2026 ValtersIT Hub
>_ SYSTEM_CORE: INTEL_ACTIVE
90% TEAM-CURATED // 10% AUTOMATED INGESTION.
ALL PATCH REFERENCES AND VERSION DATA SOURCED FROM NVD + OSV OFFICIAL REGISTRIES.