CVE-2025-13406
Executive Summary
CVE-2025-13406 is a NULL Pointer Dereference vulnerability in the Softing Industrial Automation GmbH smartLink SW-HT (Webserver modules). This flaw allows an unauthenticated, remote attacker to cause a Denial of Service (DoS) condition on the HTTP server by sending a specially crafted request that triggers a NULL pointer dereference. The vulnerability affects version 1.43 of the smartLink SW-HT product. No patch is currently available, and no public exploit code has been released. The EPSS score is 0.0%, indicating a low probability of exploitation in the wild at this time, but the risk remains significant for industrial environments relying on this device.
This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.
No signup required
CVSS Breakdown & Threat Level
The CVSS vector is not provided in the NVD data. However, based on the description (NULL Pointer Dereference leading to HTTP DoS), a reasonable assessment would be:
- Attack Vector (AV): Network (N)
- Attack Complexity (AC): Low (L)
- Privileges Required (PR): None (N)
- User Interaction (UI): None (N)
- Scope (S): Unchanged (U)
- Confidentiality (C): None (N)
- Integrity (I): None (N)
- Availability (A): High (H)
Estimated CVSS v3.1 Score: 7.5 (High) – AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Threat Level: High. The vulnerability is remotely exploitable without authentication and directly impacts availability, which is critical in industrial control system (ICS) environments.
Deep Dive & Mechanics
The vulnerability resides in the HTTP server module of the Softing smartLink SW-HT. A NULL Pointer Dereference (CWE-476) occurs when the software attempts to dereference a pointer that has not been initialized or has been set to NULL. In the context of an HTTP server, this can be triggered by sending a malformed HTTP request that causes the server to access a memory location through a NULL pointer.
Mechanism:
- The smartLink SW-HT HTTP server receives an incoming HTTP request.
- The server parses the request headers and body.
- Due to a missing or insufficient validation of a specific field or parameter, the server creates a pointer that remains NULL.
- When the server later attempts to use this pointer (e.g., to copy data, process a header, or generate a response), it dereferences the NULL pointer.
- This causes a segmentation fault or access violation, crashing the HTTP server process.
- The crash results in a Denial of Service, making the web interface and any HTTP-based services unavailable.
The vulnerability is specific to version 1.43. No patch details are available, indicating that the vendor may not have released a fix yet.
Vulnerable vs. Patched Code
Since no patch is available, a direct code comparison cannot be made. However, based on the vulnerability type, the following hypothetical code snippets illustrate the issue.
Vulnerable Code (C/C++ example):
void handle_request(http_request *req) {
char *header_value = NULL;
// Missing validation: if header "X-Custom" is not present, header_value remains NULL
header_value = get_header(req, "X-Custom");
// Dereference without NULL check
process_header_value(header_value);
}
Patched Code (Hypothetical):
void handle_request(http_request *req) {
char *header_value = NULL;
header_value = get_header(req, "X-Custom");
if (header_value == NULL) {
// Handle missing header gracefully
log_error("Missing X-Custom header");
return;
}
process_header_value(header_value);
}
The fix would involve adding a NULL check before dereferencing any pointer obtained from request parsing.
Exploitation & Lab Setup
Red Team (Exploitation):
Since no public exploit code is available, exploitation would require reverse engineering the smartLink SW-HT firmware to identify the exact request that triggers the NULL pointer dereference. A likely approach:
- Fuzzing: Use a tool like
boofuzzorwfuzzto send malformed HTTP requests to the device. - Targeted Requests: Focus on missing or malformed headers, unusual HTTP methods, or oversized payloads.
- Trigger: A request missing a specific header (e.g.,
Host,Content-Length, or a custom header) might cause the crash.
Example fuzzing command (using curl):
# Send a request without a Host header
curl -H "User-Agent: " --http1.0 http://target-ip/
Blue Team (Detection & Hardening):
- Network Segmentation: Isolate the smartLink SW-HT device on a separate VLAN with strict access controls.
- Web Application Firewall (WAF): Deploy a WAF to inspect and filter malformed HTTP requests.
- Monitoring: Monitor device logs for crashes or unexpected restarts.
- Rate Limiting: Implement rate limiting to reduce the impact of repeated DoS attempts.
Lab Setup:
- Target: Softing smartLink SW-HT (firmware version 1.43)
- Attacker Machine: Kali Linux with tools like
nmap,curl,burpsuite, andboofuzz. - Network: Isolated lab network with mirrored traffic for analysis.
Indicators of Compromise (IOCs)
- Network IOCs:
- Repeated HTTP requests with missing or malformed headers (e.g., no
Hostheader, invalidContent-Length). - Sudden increase in HTTP 400/500 error responses followed by connection timeouts.
- Device web interface becoming unresponsive.
- Repeated HTTP requests with missing or malformed headers (e.g., no
- System IOCs:
- Device logs showing segmentation faults or NULL pointer dereference errors.
- Unexpected restart of the HTTP server process.
- Memory dumps or crash logs indicating a NULL pointer access.
Detection Engineering
YARA Rule:
rule CVE_2025_13406_NULL_Pointer_Dereference {
meta:
description = "Detects potential NULL pointer dereference in Softing smartLink SW-HT HTTP server"
author = "Valters IT"
date = "2025-04-10"
cve = "CVE-2025-13406"
strings:
$s1 = "NULL pointer" nocase
$s2 = "segmentation fault" nocase
$s3 = "access violation" nocase
condition:
any of them
}
Sigma Rule:
title: CVE-2025-13406 - NULL Pointer Dereference in Softing smartLink SW-HT
id: 8a9b3c4d-5e6f-7a8b-9c0d-1e2f3a4b5c6d
status: experimental
description: Detects HTTP requests that may trigger a NULL pointer dereference in Softing smartLink SW-HT version 1.43.
author: Valters IT
date: 2025-04-10
tags:
- attack.t1499
- cve.2025.13406
logsource:
category: webserver
product: softing_smartlink
detection:
selection:
http.response.status_code: 500
http.response.body|contains: "NULL pointer"
condition: selection
falsepositives:
- Legitimate server errors
level: high
Suricata Rule:
alert http any any -> any any (msg:"CVE-2025-13406 - Potential NULL Pointer Dereference in Softing smartLink SW-HT"; flow:to_server; content:"|00|"; http_client_body; depth:1; sid:1000001; rev:1;)
Remediation & Mitigation
Immediate Actions:
- Isolate the Device: Place the smartLink SW-HT behind a firewall or VPN, limiting access to trusted IPs only.
- Disable HTTP if Unnecessary: If the web interface is not required, disable the HTTP server module.
- Monitor Logs: Enable detailed logging and monitor for crash events.
Long-Term Fix:
- Vendor Patch: Await an official firmware update from Softing Industrial Automation GmbH. Contact the vendor for a timeline.
- Workaround: If possible, upgrade to a newer version of the smartLink SW-HT that is not affected (if available).
- Compensating Controls: Deploy a reverse proxy or WAF that can sanitize HTTP requests before they reach the device.
Valters IT Signature:
Valters IT
Senior DevSecOps Engineer
Cyber Threat Intelligence Expert