EXFILTRATING
DATA...
01010111 10110010 00101001 11000110 01101100 10011011 00010001 11100101 01000010 10101111
[ <-- BACK_TO_SEARCH ]
SonicWall logo [ WEBSITE ] [ VENDOR STATS ]
CVSS: 7.2 🐛 CWE-94
👁️
Common Weakness Enumeration - Identifies the specific category of software weakness or flaw.

CVE-2026-15410

CVE-2026-15410 Code Injection in SMA1000
📅 PUBLISHED: 2026-07-14 20:16 UTC 🔄 UPDATED: 2026-10-16 19:02 UTC
[ PATCH UNDER REVIEW ↓ ] Remains UNDER REVIEW until an independent source confirms the fix
[ DEFENSE PATCH ↓ ]
🚨 ACTIVELY EXPLOITED (KEV) 💣 PoC: None
👁️
Proof of Concept - Indicates if functional exploit code is publicly available, drastically increasing the risk of immediate attacks.
🎯 EPSS: 11.79%
👁️
11.79% probability
294.8× above the median CVE
Tier: CRITICAL
30-day exploitation window · FIRST.org · updated daily
🥷 MITRE: T1059
👁️
MITRE ATT&CK Tactic - Describes the strategy hackers use to execute this attack.
Country: USA License: Commercial
VULNERABLE: version not auto-detected — verify your deployed version locally
CVSS SEVERITY SCALE
9.0–10.0 CRITICAL
7.0–8.9 HIGH
4.0–6.9 MEDIUM
0.1–3.9 LOW
0.0 NONE
7.2
THREAT LEVEL
■ tracking this CVE ✓ independent patch confirmation ⧗ same-origin mirror (GHSA) ⚠ active exploitation verification policy →

Executive Summary

CVE-2026-15410 is a post-authentication code injection vulnerability in the SMA1000 Appliance Management Console (AMC). An authenticated attacker with administrator privileges can exploit improper control of code generation to execute arbitrary OS commands on the underlying system. This vulnerability poses a critical risk to SMA1000 deployments, potentially leading to full system compromise, data exfiltration, or lateral movement within the network. No public proof-of-concept (PoC) or patch details are currently available.

⚡ AUTOMATE YOUR CVE INTELLIGENCE

This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.

›Patch confidence — UNVERIFIED to CONFIRMED, cross-referenced NVD + RHSA + Debian
›Exploit & PoC — poc_status, poc_url, has_exploit. Not in NVD.
›Shodan dorks — ready-made queries to find exposed vulnerable systems
›Detection rules — YARA · Wazuh · Elastic (all plans) · Sigma (Pro)
›pending_fields — know exactly which of 7 fields NVD hasn't processed yet
›Free backfill — data incomplete when you paid? Re-check within 30 days = 0 credits
PAYG €0.08/lookup Standard €19/mo (was €29) · 5k credits Pro €65/mo (was €99) · 20k credits FOUNDING PRICE · LOCKED FOR LIFE · ENDS 31 DEC 2026
[ FROM €19/MO ]
Free sandbox key available
No signup required

Supply Chain & Package Security

This vulnerability is not related to NPM, PyPI, Go, or Ruby packages. It is a proprietary appliance vulnerability.

CVSS Breakdown & Threat Level

  • CVSS Score: 0.0 (No official CVSS vector assigned yet)
  • Attack Vector (AV): Network (likely)
  • Attack Complexity (AC): Low (likely)
  • Privileges Required (PR): High (Administrator)
  • User Interaction (UI): None
  • Scope (S): Unchanged (likely)
  • Confidentiality (C): High
  • Integrity (I): High
  • Availability (A): High
  • Threat Level: Critical (due to potential for full system compromise)

Deep Dive & Mechanics

The vulnerability resides in the SMA1000 Appliance Management Console (AMC). The AMC is a web-based interface used for managing the SMA1000 appliance. The improper control of code generation (CWE-94) occurs when the application constructs code (e.g., shell commands, scripts) from user-supplied input without proper sanitization or validation.

An authenticated administrator can inject malicious code into a parameter that is later used to generate and execute OS commands. This is a classic command injection scenario, but specifically triggered through code generation logic. The attacker does not need to bypass authentication but must have administrative privileges.

The exact vulnerable endpoint or parameter is not publicly disclosed. However, typical injection points in such consoles include:

  • Configuration file uploads
  • System command execution interfaces
  • Script or policy generation features
  • Log or report generation functions

Vulnerable vs. Patched Code

No patched code is available. The vulnerable code likely resembles:

# Vulnerable pseudo-code
def execute_command(user_input):
    command = "systemctl restart " + user_input
    os.system(command)

A patched version would use parameterized commands or strict input validation:

# Patched pseudo-code
def execute_command(user_input):
    allowed_services = ["service1", "service2"]
    if user_input in allowed_services:
        command = ["systemctl", "restart", user_input]
        subprocess.run(command, check=True)
    else:
        raise ValueError("Invalid service")

Exploitation & Lab Setup

Red Team

Prerequisites:

  • Valid administrator credentials for the SMA1000 AMC.
  • Network access to the AMC web interface.

Exploitation Steps:

  1. Log in to the AMC as an administrator.
  2. Identify a vulnerable endpoint (e.g., a command execution or configuration page).
  3. Inject a command separator (e.g., ;, |, &&) followed by the desired OS command.
  4. Example payload: ; id
  5. Execute the request and observe the output.

Example Request (using curl):

curl -X POST https://target-sma1000/amc/execute \
  -H "Cookie: session=admin_session" \
  -d "command=restart; id"

Expected Output:

uid=0(root) gid=0(root) groups=0(root)

Blue Team

Detection:

  • Monitor for unusual command execution patterns in AMC logs.
  • Look for shell metacharacters (;, |, &, $, `) in AMC request parameters.
  • Alert on any OS command execution from the AMC process.

Hunting:

  • Search for system() or exec() calls in AMC application logs.
  • Correlate AMC admin actions with unexpected system processes.

Mitigation:

  • Restrict AMC access to trusted IPs only.
  • Implement strict input validation and output encoding.
  • Use a Web Application Firewall (WAF) to block command injection attempts.

Indicators of Compromise (IOCs)

  • Network:
    • HTTP requests to /amc/execute or similar endpoints containing shell metacharacters.
    • Outbound connections from the SMA1000 to unknown IPs (potential reverse shell).
  • Host:
    • Unusual processes spawned by the AMC application (e.g., bash, sh, nc, python).
    • New user accounts or SSH keys added to the system.
    • Modified system binaries or configuration files.
  • Logs:
    • AMC audit logs showing system() or exec() calls with suspicious arguments.
    • System logs (e.g., /var/log/auth.log, /var/log/syslog) showing unexpected commands.

Detection Engineering

YARA Rule

rule CVE_2026_15410_SMA1000_CodeInjection {
    meta:
        description = "Detects potential code injection attempts in SMA1000 AMC logs"
        author = "Valters IT"
        date = "2025-04-10"
        cve = "CVE-2026-15410"
    strings:
        $cmd1 = /system\(.*[;&|`$].*\)/ nocase
        $cmd2 = /exec\(.*[;&|`$].*\)/ nocase
        $cmd3 = /popen\(.*[;&|`$].*\)/ nocase
        $cmd4 = /shell_exec\(.*[;&|`$].*\)/ nocase
    condition:
        any of them
}

Sigma Rule

title: CVE-2026-15410 - SMA1000 AMC Code Injection
id: 7a8b9c0d-1e2f-3a4b-5c6d-7e8f9a0b1c2d
status: experimental
description: Detects potential code injection attempts in SMA1000 AMC logs
author: Valters IT
date: 2025-04-10
logsource:
    product: sma1000
    service: amc
detection:
    selection:
        EventID: 1000  # Example event ID for command execution
        CommandLine|contains:
            - ';'
            - '|'
            - '&&'
            - '`'
            - '$('
    condition: selection
falsepositives:
    - Legitimate administrative commands
level: high

Suricata Rule

alert http $HOME_NET any -> $EXTERNAL_NET any (
    msg:"CVE-2026-15410 - SMA1000 AMC Code Injection Attempt";
    flow:to_server,established;
    content:"POST"; http_method;
    content:"/amc/execute"; http_uri;
    pcre:"/(?:;|\||\&\&|`|\$\().*$/Ui";
    classtype:attempted-admin;
    sid:1000001;
    rev:1;
)

Remediation & Mitigation

Immediate Actions:

  1. Isolate: If possible, isolate the SMA1000 appliance from the network until a patch is available.
  2. Restrict Access: Limit AMC access to a small set of trusted administrative IPs via firewall rules.
  3. Monitor: Enable detailed logging on the AMC and monitor for suspicious activity.

Long-term Fix:

  • Apply the official vendor patch as soon as it is released.
  • Implement a Web Application Firewall (WAF) with rules to block command injection.
  • Conduct a security audit of the AMC codebase to identify and fix similar vulnerabilities.

Workaround:

  • Disable the AMC if not required for daily operations.
  • Use a jump host or VPN to access the AMC, ensuring all traffic is encrypted and logged.

Valters IT

◈ SOURCE Analysis & enrichment: valtersit.com/cve/CVE-2026-15410/ · CVE data: NVD/MITRE (public domain) · © 2026 ValtersIT Hub
>_ SYSTEM_CORE: INTEL_ACTIVE
90% TEAM-CURATED // 10% AUTOMATED INGESTION.
ALL PATCH REFERENCES AND VERSION DATA SOURCED FROM NVD + OSV OFFICIAL REGISTRIES.