CVE-2026-27518

CVE-2026-27518 Cross-Site Request Forgery in Binardat
📅 PUBLISHED: 2026-02-24 15:06 UTC 🔄 UPDATED: 2026-09-23 20:33 UTC
[ PATCH UNDER REVIEW ↓ ] Remains UNDER REVIEW until an independent source confirms the fix
[ DEFENSE PATCH ↓ ]
💣 PoC: None
👁️
Proof of Concept - Indicates if functional exploit code is publicly available, drastically increasing the risk of immediate attacks.
🎯 EPSS: 0.10%
👁️
0.10% probability
2.6× above the median CVE
Tier: ELEVATED
30-day exploitation window · FIRST.org · updated daily
Country: United States License: Commercial
VULNERABLE: version not auto-detected — verify your deployed version locally
CVSS SEVERITY SCALE
9.0–10.0 CRITICAL
7.0–8.9 HIGH
4.0–6.9 MEDIUM
0.1–3.9 LOW
0.0 NONE
5.1
THREAT LEVEL
■ tracking this CVE ✓ independent patch confirmation ⧗ same-origin mirror (GHSA) ⚠ active exploitation verification policy →

Executive Summary

CVE-2026-27518 is a critical Cross-Site Request Forgery (CSRF) vulnerability affecting Binardat 10G08-0800GSM network switches running firmware version V300SP10260209 and prior. The administrative interface lacks CSRF protections for state-changing actions, allowing an attacker to trick an authenticated administrator into performing unauthorized configuration changes. This can lead to complete compromise of the switch configuration, including VLAN changes, port disabling, or credential modification. No public exploit code or patch is currently available.

⚡ AUTOMATE YOUR CVE INTELLIGENCE

This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.

›Patch confidence — UNVERIFIED to CONFIRMED, cross-referenced NVD + RHSA + Debian
›Exploit & PoC — poc_status, poc_url, has_exploit. Not in NVD.
›Shodan dorks — ready-made queries to find exposed vulnerable systems
›Detection rules — YARA · Wazuh · Elastic (all plans) · Sigma (Pro)
›pending_fields — know exactly which of 7 fields NVD hasn't processed yet
›Free backfill — data incomplete when you paid? Re-check within 30 days = 0 credits
PAYG €0.08/lookup Standard €19/mo (was €29) · 5k credits Pro €65/mo (was €99) · 20k credits FOUNDING PRICE · LOCKED FOR LIFE · ENDS 31 DEC 2026
[ FROM €19/MO ]
Free sandbox key available
No signup required

Supply Chain & Package Security

This vulnerability is not related to any software package manager (NPM, PyPI, Go, Ruby). It is a firmware-level issue in a network hardware appliance.

CVSS Breakdown & Threat Level

CVSS Score: 6.1 (Medium) Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N

  • Attack Vector (AV): Network – The attack is performed over the network.
  • Attack Complexity (AC): Low – No special conditions required.
  • Privileges Required (PR): None – The attacker does not need authentication.
  • User Interaction (UI): Required – The victim must be an authenticated administrator who clicks a malicious link.
  • Scope (S): Unchanged – The vulnerable component and the attacker’s scope are the same.
  • Confidentiality (C): None – No data exfiltration.
  • Integrity (I): High – Full configuration modification possible.
  • Availability (A): None – No direct denial of service.

Threat Level: Medium. While the CVSS score is moderate, the potential for full network disruption elevates the risk in operational environments.

Deep Dive & Mechanics

The vulnerability resides in the web-based administrative interface of the Binardat 10G08-0800GSM switch. The interface handles state-changing operations (e.g., modifying VLANs, changing passwords, enabling/disabling ports) via HTTP POST requests. These requests lack CSRF tokens or any origin/Referer validation.

Attack Flow:

  1. The attacker crafts a malicious HTML page containing an auto-submitting form that targets the switch’s administrative interface.
  2. The attacker lures an authenticated administrator to visit this page (e.g., via phishing email or compromised website).
  3. The administrator’s browser automatically sends the forged request, including any session cookies, to the switch.
  4. The switch processes the request as legitimate, executing the attacker’s desired configuration change.

Root Cause: Absence of anti-CSRF mechanisms such as synchronizer tokens, SameSite cookies, or custom headers.

Vulnerable vs. Patched Code

Vulnerable Code (Conceptual):

# Example of vulnerable handler (pseudo-code)
def handle_config_change(request):
    # No CSRF token check
    if request.method == 'POST':
        apply_config(request.POST)
        return "Configuration updated"

Patched Code (Conceptual):

# Example of patched handler (pseudo-code)
import secrets

def generate_csrf_token():
    return secrets.token_urlsafe(32)

def handle_config_change(request):
    if request.method == 'POST':
        token = request.POST.get('csrf_token')
        if not token or token != session['csrf_token']:
            return "CSRF validation failed", 403
        apply_config(request.POST)
        return "Configuration updated"

The patched version generates a unique CSRF token per session and validates it on every state-changing request.

Exploitation & Lab Setup

Red Team

Lab Environment:

  • Binardat 10G08-0800GSM switch with firmware V300SP10260209
  • Attacker machine (Kali Linux)
  • Victim machine (Windows/Linux with browser)
  • Network connectivity between all hosts

Exploitation Steps:

  1. Identify the switch’s IP address and administrative interface URL (e.g., http://192.168.1.1/admin).
  2. Craft a malicious HTML page that performs a state-changing action (e.g., changing the admin password):
    <html>
    <body>
    <form action="http://192.168.1.1/admin/password" method="POST">
        <input type="hidden" name="new_password" value="attacker123">
        <input type="hidden" name="confirm_password" value="attacker123">
        <input type="submit" value="Click me">
    </form>
    <script>document.forms[0].submit();</script>
    </body>
    </html>
    
  3. Host this page on a web server accessible to the victim.
  4. Send a phishing email to the administrator with a link to the malicious page.
  5. Once the administrator clicks the link and is authenticated to the switch, the password is changed.
  6. Log in with the new password to gain full administrative access.

Note: No public exploit code is available. The above is a conceptual demonstration.

Blue Team

Detection & Prevention:

  • Monitor for unusual HTTP POST requests to the switch’s administrative interface from unexpected origins.
  • Implement network segmentation to restrict access to the management interface.
  • Use a web application firewall (WAF) to inspect and block requests lacking CSRF tokens.
  • Educate administrators about phishing attacks targeting network devices.

Indicators of Compromise (IOCs)

  • Network Traffic:
    • HTTP POST requests to /admin/password, /admin/vlan, or similar endpoints without a Referer header matching the switch’s domain.
    • Multiple failed login attempts from a single IP after a CSRF attack.
  • Logs:
    • Switch logs showing configuration changes without corresponding user session activity.
    • Unexpected password changes or VLAN modifications.
  • Files:
    • Malicious HTML files hosted on external servers targeting the switch’s IP.

Detection Engineering

YARA Rule

rule CVE_2026_27518_CSRF_Exploit {
    meta:
        description = "Detects HTML pages attempting CSRF against Binardat switches"
        author = "Valters IT"
        date = "2026-01-01"
        reference = "CVE-2026-27518"
    strings:
        $csrf_form = /<form\s+action=["']http:\/\/[^"']*\/admin\// nocase
        $csrf_method = /method=["']POST["']/ nocase
        $csrf_hidden = /<input\s+type=["']hidden["']/ nocase
    condition:
        all of them
}

Sigma Rule

title: Binardat Switch CSRF Exploit Attempt
id: 8f3a2b1c-4d5e-6f7a-8b9c-0d1e2f3a4b5c
status: experimental
description: Detects HTTP POST requests to Binardat switch admin endpoints without proper Referer header
author: Valters IT
date: 2026-01-01
logsource:
    category: webserver
    product: apache
detection:
    selection:
        cs-method: 'POST'
        cs-uri-stem|startswith: '/admin/'
        cs-referer|contains: 'http://'
    filter:
        cs-referer|contains: '192.168.1.1'  # Adjust to switch IP
    condition: selection and not filter
falsepositives:
    - Legitimate admin actions from authorized hosts
level: high

Suricata Rule

alert http $HOME_NET any -> $EXTERNAL_NET any (
    msg:"CVE-2026-27518 Binardat Switch CSRF Attempt";
    flow:to_server,established;
    content:"POST"; http_method;
    content:"/admin/"; http_uri;
    pcre:"/Referer:\s*http:\/\/(?!192\.168\.1\.1)/Hi";
    sid:1000001;
    rev:1;
    reference:cve,2026-27518;
    classtype:attempted-admin;
    priority:2;
)

Remediation & Mitigation

Immediate Actions:

  1. Isolate Management Interface: Place the switch’s administrative interface on a separate management VLAN with strict access controls.
  2. Disable Unused Services: If remote management is not required, disable the web interface and use only console access.
  3. Implement VPN: Require VPN access for any administrative actions to add an additional layer of authentication.

Long-Term Fix:

  • Vendor Patch: Contact Binardat for a firmware update that includes CSRF protections. As of now, no patch is available.
  • Workaround: Use a reverse proxy (e.g., Nginx) in front of the switch to inject CSRF tokens or validate Referer headers.

Monitoring:

  • Enable logging on the switch and monitor for unauthorized configuration changes.
  • Deploy the provided detection rules to identify exploitation attempts.

Valters IT