EXFILTRATING
DATA...
01010111 10110010 00101001 11000110 01101100 10011011 00010001 11100101 01000010 10101111
[ <-- BACK_TO_SEARCH ]
[ VENDOR STATS ]
CVSS: 6.8 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N 🐛 CWE-35
👁️
Common Weakness Enumeration - Identifies the specific category of software weakness or flaw.

CVE-2026-44414

CVE-2026-44414 Vulnerability in Siemens
📅 PUBLISHED: 2026-10-13 00:00 UTC 🔄 UPDATED: 2026-10-14 05:00 UTC
[ ZERO-DAY / UNPATCHED ] [ DEFENSE PATCH ↓ ]
💣 PoC: Public
👁️
Proof of Concept - Indicates if functional exploit code is publicly available, drastically increasing the risk of immediate attacks.
🥷 MITRE: T1190
👁️
MITRE ATT&CK Tactic - Describes the strategy hackers use to execute this attack.
VULNERABLE: Industrial Edge Device Kit - arm64 V1.5 - V1.28; Industrial Edge Device Kit - x86-64 V1.10 - V1.16 (and as listed)
CVSS VECTOR BREAKDOWN 6.8
AV: N Attack Vector Network
AC: L Attack Complexity Low
PR: H Privileges Required High
UI: N User Interaction None
S: C Scope Changed
C: H Confidentiality High
I: N Integrity None
A: N Availability None
6.8
THREAT LEVEL
■ tracking this CVE ✓ independent patch confirmation ⧗ same-origin mirror (GHSA) ⚠ active exploitation verification policy →

Executive Summary

CVE-2026-44414 is a path traversal vulnerability (CWE-35, "Path Traversal: '.../...//'") affecting Siemens Industrial Edge Cloud Device (IECD) and Industrial Edge Device Kit components across a broad range of arm64 and x86-64 releases (V1.5 through V1.28). An authenticated, highly privileged attacker can traverse outside the intended directory and access files outside the application's expected scope, resulting in high confidentiality impact. With a CVSS v3.1 base score of 6.8 (AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N), exploitation requires privileged access but yields cross-boundary disclosure of sensitive data, making it a meaningful risk in OT/edge deployments where the Device Kit manages containers, apps, and device credentials.

⚡ AUTOMATE YOUR CVE INTELLIGENCE

This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.

›Patch confidence — UNVERIFIED to CONFIRMED, cross-referenced NVD + RHSA + Debian
›Exploit & PoC — poc_status, poc_url, has_exploit. Not in NVD.
›Shodan dorks — ready-made queries to find exposed vulnerable systems
›Detection rules — YARA · Wazuh · Elastic (all plans) · Sigma (Pro)
›pending_fields — know exactly which of 7 fields NVD hasn't processed yet
›Free backfill — data incomplete when you paid? Re-check within 30 days = 0 credits
PAYG €0.08/lookup Standard €19/mo (was €29) · 5k credits Pro €65/mo (was €99) · 20k credits FOUNDING PRICE · LOCKED FOR LIFE · ENDS 31 DEC 2026
[ FROM €19/MO ]
Free sandbox key available
No signup required

Technical Analysis

The vulnerability is a path traversal flaw classified as CWE-35, a variant where directory traversal sequences are manipulated (for example through sequences like ".../...//") to bypass naive input sanitization. The NVD description names the affected products — Siemens Industrial Edge Cloud Device (IECD) and the Industrial Edge Device Kit for both arm64 and x86-64 architectures — across an extensive version list (arm64 V1.5–V1.28; x86-64 V1.10–V1.16 and later).

Path traversal occurs when user-controllable input that is meant to reference a file or path is not adequately normalized or constrained before being used in filesystem operations. Instead of injecting OS command syntax or SQL, the attacker supplies traversal sequences that cause the resolved path to point outside the intended base directory. Because CWE-35 specifically references the "double-dot with trailing slash" bypass, this suggests the implementation's sanitization or filtering logic can be evaded by crafted traversal encodings, allowing the attacker to read files the application would otherwise restrict.

The attack surface is network-reachable (AV:N) and requires only low attack complexity (AC:L), but the vector specifies PR:H — meaning the attacker must already hold privileged credentials/roles on the affected component. No user interaction is needed (UI:N). The scope change (S:C) indicates the traversal crosses a security boundary, and the confidentiality impact is High (C:H) while integrity and availability are None — consistent with a pure file-read/disclosure flaw rather than code execution or data destruction. The CNA title field is empty and the description provides no specific function names, endpoints, or parameters; therefore no code-level identifiers are asserted here.

Exploitation Scenarios

No public PoC, exploit code, or Nuclei template is available. The following chain is inferred from the vulnerability class (CWE-35 path traversal) and the CVSS vector; it does not assert specific function, parameter, or endpoint names that are absent from the source data.

  1. Reconnaissance / target identification: The attacker identifies a reachable Siemens Industrial Edge Device Kit or IECD instance (e.g., via network scanning or Shodan queries for Industrial Edge deployments). They confirm the target version falls within the affected ranges (arm64 V1.5–V1.28, x86-64 V1.10+).

  2. Triggering the flaw: Using privileged access (PR:H), the attacker submits input containing traversal sequences to a file- or path-handling feature of the Device Kit. Crafted ".../...//" style encodings are used to evade sanitization and cause the resolved path to escape the intended directory. Because AC:L and UI:N, once the request is built it can be delivered directly without timing or user-assistance constraints.

  3. Execution method: The attacker issues a network request (AV:N) that the component processes as a file/path reference. Rather than achieving code execution, the objective is to make the application return or process a file located outside its allowed scope.

  4. Post-exploitation impact: Successful traversal discloses files outside intended boundaries (C:H), potentially including configuration, credential, or system files, with the security-scope change (S:C) indicating impact beyond the vulnerable component's own boundary. There is no integrity or availability impact (I:N/A:N), consistent with a read-only disclosure primitive that can nonetheless enable follow-on attacks (credential reuse, lateral movement).

Impact Assessment

The business impact centers on confidentiality loss in industrial edge environments. Affected systems are Siemens Industrial Edge Cloud Device (IECD) and Industrial Edge Device Kit deployments (arm64 V1.5–V1.28; x86-64 as listed), which commonly host and orchestrate edge applications and containers in OT networks. A path traversal that reads files outside the application's directory can expose sensitive configuration, device credentials, or application data.

CVSS subscores map as follows: AV:N — exploitable over the network; AC:L — no special conditions for success; PR:H — requires privileged access, which limits the attacker pool to insiders, compromised privileged accounts, or attackers who have already escalated to a privileged role; UI:N — no victim interaction; S:C — the impact crosses a security authority boundary; C:H — high confidentiality impact (broad file disclosure); I:N / A:N — no integrity or availability effects. The 6.8 base score reflects high confidentiality impact tempered by the privileged-access prerequisite. Blast radius includes any edge deployment where a privileged user or compromised privileged session exists and where sensitive files reside on the same host or within the vulnerable component's reachable filesystem scope. Because it is unpatched, exposures persist until a vendor fix or mitigation is applied.

Detection Guidance

Sigma Rule

title: Potential Path Traversal Attempt Against Siemens Industrial Edge Device Kit (CVE-2026-44414)
id: 8f2a1c74-3b6e-4d21-9a55-2c7e0f9d4b13
status: experimental
description: Detects HTTP requests containing directory traversal sequences, including the ".../...//" double-dot-with-trailing-slash bypass pattern (CWE-35), targeting Siemens Industrial Edge components.
references:
  - https://nvd.nist.gov/vuln/detail/CVE-2026-44414
author: valtersit.com
date: 2026/01/01
logsource:
  category: webserver
detection:
  selection_methods:
    cs-method:
      - GET
      - POST
  selection_traversal:
    cs-uri-query|contains:
      - '..%2f'
      - '%2e%2e%2f'
      - '../'
      - '.../...//'
      - '....//'
      - '..%252f'
      - '%252e%252e%252f'
  condition: selection_methods and selection_traversal
falsepositives:
  - Legitimate applications or scanners using encoded path segments
  - Security assessment tooling
level: medium
tags:
  - attack.initial_access
  - attack.t1190
  - cve.2026.44414

YARA Rule

rule CVE_2026_44414_PathTraversal_Indicators
{
    meta:
        description = "Detects path traversal payload indicators including CWE-35 double-dot-with-trailing-slash bypass patterns for CVE-2026-44414"
        author = "valtersit.com"
        reference = "https://nvd.nist.gov/vuln/detail/CVE-2026-44414"
        date = "2026-01-01"
        cve = "CVE-2026-44414"
        severity = "medium"

    strings:
        $trav1 = "....//" ascii wide nocase
        $trav2 = ".../...//" ascii wide nocase
        $trav3 = "..%2f..%2f" ascii nocase
        $trav4 = "%2e%2e%2f" ascii nocase
        $trav5 = "..%252f" ascii nocase
        $trav6 = "etc/passwd" ascii nocase
        $trav7 = "..\\..\\" ascii wide nocase

    condition:
        uint16(0) == 0x5A4D or // PE
        uint32(0) == 0x464C457F or // ELF
        any of ($trav*)
}

Suricata IDS Rule

alert http any any -> any any (msg:"CVE-2026-44414 Siemens Industrial Edge Path Traversal Attempt (CWE-35)"; flow:established,to_server; http.method; content:"GET"; http.uri; content:"../"; nocase; http.uri; content:".../...//"; nocase; classtype:attempted-recon; reference:cve,2026-44414; reference:url,nvd.nist.gov/vuln/detail/CVE-2026-44414; sid:202644414; rev:1;)

Elastic Detection

sequence by source.ip with maxspan=30s
  [ network where network.protocol == "http" and
      url.path like~ "*../*" and
      url.path like~ "*.../...//*" ]

Splunk SPL Query

index=web OR index=proxy
| search (uri="*../*" OR uri="*.../...//*" OR uri="*%2e%2e%2f*" OR uri="*%252e%252e%252f*" OR uri="*....//*")
| stats count values(uri) as uris values(status) as statuses by src_ip, dest_ip, user
| where count > 0
| sort - count

Wazuh OSSEC Rule

<group name="web,appsec,cve-2026-44414,">
  <rule id="20264414" level="10">
    <decoded_as>web-accesslog</decoded_as>
    <match>../</match>
    <regex>\.\.\./\.\.\.//|\.\.\.\.//|%2e%2e%2f|%252e%252e%252f</regex>
    <description>CVE-2026-44414: Siemens Industrial Edge path traversal attempt (CWE-35) detected</description>
    <mitre>
      <id>T1190</id>
    </mitre>
    <group>cve_2026_44414,attack.initial_access,</group>
  </rule>
</group>

Mitigation & Patch Guidance

Patch confidence: 0/4 (UNPATCHED — no patch evidence from any tracked source). No vendor fix, workaround, or fixed version has been identified in the tracked sources. The following are general recommendations for this vulnerability class.

  1. Immediate mitigations:
  • Restrict network exposure of Industrial Edge Device Kit / IECD management interfaces to trusted management networks and segment them from broader OT/IT traffic.
  • Enforce least privilege and review privileged accounts (PR:H is required), as only highly privileged users can currently trigger the flaw — reduce the number of such accounts and monitor their activity.
  • Deploy the detection content above (Sigma/YARA/Suricata/Elastic/Splunk/Wazuh) to identify traversal attempts containing ".../...//" and related encodings.
  • Where possible, place affected components behind an application-aware reverse proxy or WAF configured to normalize and reject traversal sequences.
  1. Patch/upgrade steps:
  • Monitor Siemens ProductCERT / Siemens Industrial Edge security advisories directly for an official fix referencing CVE-2026-44414 and apply it when released.
  • Track the affected version matrix (arm64 V1.5–V1.28; x86-64 V1.10–V1.16 and later) to determine which installed releases require updating.
  • Until a fix is available, isolate affected devices and limit privileged access as above.
  1. Long-term hardening:
  • Enforce strict input validation and canonical path resolution (rejecting ".." and encoded traversal) on any custom application; this is a design-level control for CWE-35.
  • Apply role-based access control and audit logging for privileged operations on edge devices.
  • Maintain an asset inventory of Industrial Edge deployments and subscribe to Siemens advisory feeds for timely patch notification.

References

No public PoC, exploit code, or evidenced in-the-wild campaign was identified in the provided data.

👁️ SHODAN DORKS (THREAT HUNTING)

What is this? Security researchers use these exact search queries on Shodan.io (a search engine for internet-connected devices) to find vulnerable systems globally. You can copy these dorks to see if your organization's IP space is exposed.

product:"Siemens"
title:"Siemens"

💣 PoC CODE AVAILABLE

Exploit code for this CVE is tracked in our database. Access poc_code via API Pro.

[ API_PRO ] →
◈ SOURCE Analysis & enrichment: valtersit.com/cve/CVE-2026-44414/ · CVE data: NVD/MITRE (public domain) · © 2026 ValtersIT Hub
>_ SYSTEM_CORE: INTEL_ACTIVE
90% TEAM-CURATED // 10% AUTOMATED INGESTION.
ALL PATCH REFERENCES AND VERSION DATA SOURCED FROM NVD + OSV OFFICIAL REGISTRIES.