CVE-2026-75548
Executive Summary
CVE-2026-75548 is an unauthenticated clickjacking vulnerability affecting the web management interface of certain Ebyte network devices. The flaw permits a remote attacker to embed the device's administrative interface within a malicious external frame, tricking an authenticated administrator into unknowingly performing configuration changes or disruptive actions. With a CVSS base score of 5.4 (Medium), the vulnerability enables limited confidentiality and integrity impact, though it requires user interaction to exploit. As of the latest data, no vendor patch exists, and the affected product and version range remain unidentified.
This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.
No signup required
Technical Analysis
CVE-2026-75548 is classified under CWE-1021, which covers improper restriction of rendered UI layers or frames — commonly known as clickjacking (UI redressing). The underlying flaw is that the Ebyte device's web management interface fails to send X-Frame-Options HTTP headers or implement frame-busting JavaScript (e.g., frame-ancestors CSP directives). Consequently, the administrative login page and post-authentication management views are renderable within <iframe> elements hosted on attacker-controlled domains.
The attack surface is the device's HTTP/HTTPS administrative web server. The NVD description indicates that the interface does not restrict rendering within an external frame; this is a client-side security control deficiency. No authentication is required to trigger the vulnerability — the attacker only needs to craft a page that loads the victim's Ebyte device UI in a frame. However, the impact (configuration alterations, disruptive actions) materializes only when an authenticated administrator interacts with the framed content. This aligns with the CVSS vector PR:N (no privileges required to exploit) and UI:R (user interaction required for impact).
The specific technical mechanism is as follows:
- The Ebyte management interface serves HTML responses without anti-framing protections.
- An attacker creates a webpage with a transparent or deceptive overlay that embeds the Ebyte UI in an iframe, typically using CSS to position the target UI elements beneath a visually benign set of controls.
- The authenticated administrator visits the malicious page (via phishing email or other social engineering) and, believing they are clicking a button on the attacker's page, actually clicks buttons or submits forms inside the embedded Ebyte UI.
- Since the administrator's browser maintains an active session cookie with the Ebyte device, the forged clicks execute with the administrator's privileges.
No information is available regarding specific URL paths, parameter names, or function names — the NVD description does not provide implementation-level detail. The vulnerability class alone suffices to explain the exposure, and we should not speculate on product-specific HTTP endpoints.
Exploitation Scenarios
The attack chain is inferred from the vulnerability class (clickjacking). No public PoC, exploit code, or Nuclei template exists for CVE-2026-75548 at the time of analysis. The steps below reflect the standard clickjacking exploitation pattern adapted to the NVD description.
Step 1 — Reconnaissance / Target Identification The attacker identifies an Ebyte device hosting a web management interface exposed to the network (e.g., via Shodan or direct scanning of IP ranges). The attacker determines the device's IP address or hostname and verifies that the admin interface is reachable. The attacker also identifies a legitimate administrator user of that device, typically through social engineering reconnaissance (internal directory, LinkedIn, or network enumeration).
Step 2 — Triggering the Flaw Class
The attacker crafts a malicious HTML page hosted on an external domain. The page constructs an invisible or deceptively styled <iframe> whose src attribute points to the Ebyte device's management interface URL. Because the Ebyte server does not send X-Frame-Options: DENY/SAMEORIGIN or a CSP frame-ancestors directive, the browser renders the Ebyte UI inside the frame without restriction.
Step 3 — Payload / Execution at the Vulnerability-Class Level The attacker overlays the framed Ebyte UI with a set of decoy UI elements (e.g., a fake "Claim Bonus" button or a survey prompt). Using CSS (opacity, z-index, pointer-events), the attacker aligns the decoy button's coordinates precisely over a target administrative action in the framed Ebyte UI — for example, a "Reboot Device," "Restore Factory Defaults," or "Apply Configuration" button. When the authenticated administrator clicks the visible decoy, the browser routes the click to the Ebyte button underneath, executing the administrative action. In a variant, the attacker may use form auto-submit scripting if the framed page permits cross-origin DOM manipulation — though modern browsers block cross-origin scripted access, so the primary vector is pure click-coordinate redressing rather than programmatic DOM control.
Step 4 — Post-Exploitation Impact The impact manifests as unintended configuration changes or disruptive actions performed on the Ebyte device with administrator privileges. Consequences may include: altered network settings (causing service disruption), disabled security features, changed admin credentials (lockout), or factory reset. The attacker gains no direct code execution or data exfiltration from the device itself; the CVSS score (5.4) reflects limited confidentiality (C:L) and integrity (I:L) impact. Full impact realization depends on what administrative actions the framed interface exposes to the click-coordinate redressing.
Additional Notes: No public PoC is available. The attack chain is inferred purely from the clickjacking vulnerability class and the description of "misleading an authenticated administrator into initiating unintended configuration changes or disruptive actions."
Impact Assessment
Business Impact: The Ebyte devices affected (exact model unknown) serve as network infrastructure components. Successful exploitation leads to unauthorized administrative actions performed under the guise of the legitimate administrator, potentially causing service interruption, unauthorized reconfiguration of network settings, or device lockout. In industrial or remote-deployment contexts where these devices manage serial-to-Ethernet conversion or similar functions, downtime translates directly to operational losses.
Affected Systems: All Ebyte devices running the vulnerable web management interface. No specific firmware version list exists in the CVE data; the entire product line may be affected until patched.
Blast Radius: The attack requires the attacker to lure an authenticated administrator to a malicious webpage — a social engineering dependency. However, the attack is network-based (AV:N), requires low attack complexity (AC:L), and needs no prior authentication to set up (PR:N). The confidentiality impact (C:L) suggests that an attacker might observe limited UI-inferred data via screen capture if the frame exposes sensitive configuration values to the attacker's script (though cross-origin reads are typically blocked). The integrity impact (I:L) is the more realistic outcome: unauthorized state changes to the device configuration. No availability impact is scored (A:N), which is notable given the description mentions "disruptive actions" — the NVD scoring team assessed that even disruptive actions do not constitute a systemic availability loss in their scoring model, or that such actions are configuration changes rather than persistent DoS.
CVSS Rationale (derived from vector): AV:N (remotely exploitable), AC:L (no special conditions), PR:N (no auth needed to deploy the malicious page), UI:R (victim must click), S:U (scope unchanged — the compromised component is the device UI, not adjacent systems), C:L/I:L/A:N.
Detection Guidance
The following detection rules aim to identify either (a) HTTP responses from Ebyte devices lacking anti-framing headers, or (b) HTTP requests from browsers that include Referer headers pointing to non-Ebyte domains while loading the Ebyte admin interface — a hallmark of iframe embedding from external origins.
Sigma Rule
title: Ebyte Device Admin Interface Loaded Without Anti-Framing Headers
id: 6e3f9b2a-1c4d-4e5f-9a8b-2c3d4e5f6a7b
status: experimental
description: Detects HTTP responses from an Ebyte device web management interface that omit X-Frame-Options and Content-Security-Policy frame-ancestors headers, indicating clickjacking susceptibility.
logsource:
category: web_server
product: generic
detection:
selection_ebyte_ui:
cs-uri-extension:
- '*.htm'
- '*.html'
- '*.cgi'
- '*admin*'
- '*config*'
cs-host: contains Ebyte device IP or hostname
filter_header_framing:
sc-header: "X-Frame-Options: "
sc-header|endswith: "DENY"
filter_header_csp:
sc-header|contains: "frame-ancestors"
condition: selection_ebyte_ui and not (filter_header_framing or filter_header_csp)
level: medium
YARA Rule
rule Ebyte_Clickjacking_Admin_HTML
{
meta:
author = "Valterit SOC"
description = "Detects HTML content from Ebyte device admin pages lacking frame protection"
cve = "CVE-2026-75548"
strings:
$meta_ebyte = "Ebyte" nocase
$meta_login = "password" nocase
$meta_frame_ok_1 = "X-Frame-Options"
$meta_frame_ok_2 = "frame-ancestors"
$script_js = "<script" nocase
condition:
uint16(0) == 0x3C21 // starts with "<!"
and $meta_ebyte and $meta_login
and not ($meta_frame_ok_1 or $meta_frame_ok_2)
}
Suricata IDS Rule
alert http any any -> $HOME_NET any (msg:"ET MALWARE Ebyte Admin Interface Response Lacking Frame Protection - Possible CVE-2026-75548"; flow:established,to_client; http.response_body; content:"<html";
content:"Ebyte"; nocase; content:"password"; nocase;
reference:cve,2026-75548; classtype:attempted-user; sid:2026755481; rev:1;)
Elastic Detection
sequence by host.name with maxspan=30s
[ network where destination.port in (80, 443, 8080) and process.name : "browser*" ]
[ http where http.request.referrer != "" and http.request.referrer not contains "abye"
and http.response.status_code == 200 and http.response.headers["x-frame-options"] == null ]
[ file where event.action == "open" and file.name : "*.html" and file.path contains "Temp" ]
Splunk SPL Query
index=web sourcetype=access_combined
| eval has_xfo = if(mvfind(sc_headers, "X-Frame-Options") != "", 1, 0)
| eval has_csp = if(mvfind(sc_headers, "frame-ancestors") != "", 1, 0)
| search cs_uri_path IN ("*.htm" OR "*.html" OR "*admin*" OR "*config*")
| where has_xfo=0 AND has_csp=0
| stats count by src_ip, cs_host, sc_status, _time
| sort - _time
Wazuh OSSEC Rule
<group name="local,attack,">
<rule id="100518" level="8">
<decoded_as>json</decoded_as>
<field name="event.module">apache</field>
<field name="http.response.headers.x-frame-options">^$</field>
<field name="url" type="pcre2">(?i)(admin|config|management|setup)</field>
<description>Ebyte device admin URL accessed with no frame protection - possible clickjacking attempt (CVE-2026-75548)</description>
<group>web_application_attack</group>
<mitre>
<id>T1204</id>
</mitre>
</rule>
</group>
Mitigation & Patch Guidance
Patch Confidence: 0/4 — UNPATCHED. No vendor advisory, fix, or patch source has been identified from any tracked channel. The affected Ebyte product and version range remain unannounced.
1) Immediate Mitigations (compensating controls):
- Restrict the Ebyte web management interface to trusted administrative IPs only via network ACLs or firewall rules. This prevents external browsers from reaching the UI, cutting off the clickjacking vector entirely for remote attackers.
- If the admin interface must remain network-accessible, consider placing it behind a VPN and denying direct external access.
- Educate administrators to never browse untrusted websites while logged into the Ebyte device management console. Use a dedicated browser profile or separate machine for all device administration.
- Deploy a web application firewall (WAF) or reverse proxy in front of the device that injects
X-Frame-Options: DENYandContent-Security-Policy: frame-ancestors 'none'headers into responses from the Ebyte UI.
2) Patch/Upgrade Steps:
- Monitor the Ebyte vendor advisory page and security bulletin mailing list for a firmware release addressing CVE-2026-75548.
- Frequently check NVD and MITRE records for updates to this CVE; when a fixed firmware version is published, upgrade all affected devices immediately.
- As an interim measure, check if the Ebyte device supports custom HTTP response headers via its web server configuration or CLI — if so, manually add
X-Frame-Options: DENY.
3) Long-Term Hardening:
- Request the vendor to implement frame-ancestors CSP and X-Frame-Options headers in all future firmware.
- Implement a device-management security baseline: disable the web interface when not actively needed, or replace it with CLI-only access via SSH.
- Segment the network so that management interfaces are isolated from general user traffic zones.
- Deploy browser hardening extensions (e.g., NoScript) that block cross-origin iframes on untrusted pages, in the security team's browser fleet.
References
- NVD Entry: https://nvd.nist.gov/vuln/detail/CVE-2026-75548
- MITRE CVE Record: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2026-75548
- CWE-1021 Reference: https://cwe.mitre.org/data/definitions/1021.html (Improper Restriction of Rendered UI Layers or Frames)
- OWASP Clickjacking Defense Cheat Sheet: https://cheatsheetseries.owasp.org/cheatsheets/Clickjacking_Defense_Cheat_Sheet.html
- CISA KEV Catalog: Not listed (checked — no KEV inclusion, no known in-the-wild campaigns reported)
Threat Actor Intelligence Note: No threat actor campaigns, exploit-in-the-wild evidence, or public PoC exist for CVE-2026-75548 as of this report's compilation. The EPSS score has not yet been assigned by FIRST.org. This vulnerability is currently theoretical in exploitation scope, though the clickjacking class is well-understood and trivially exploitable when the anti-framing headers are absent — making rapid weaponization plausible in the short term.
What is this? Security researchers use these exact search queries on Shodan.io (a search engine for internet-connected devices) to find vulnerable systems globally. You can copy these dorks to see if your organization's IP space is exposed.