☠️
EXFILTRATING
DATA...
01010111 10110010 00101001 11000110 01101100 10011011 00010001 11100101 01000010 10101111
[ <-- BACK_TO_SEARCH ]
[ VENDOR STATS ]
CVSS: 9.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 🐛 CWE-494
👁️
Common Weakness Enumeration - Identifies the specific category of software weakness or flaw.

CVE-2024-48974

CVE-2024-48974
📅 PUBLISHED: 2024-11-14 00:00 UTC 🔄 UPDATED: 2026-09-23 19:41 UTC
[ PATCH UNDER REVIEW ↓ ] Remains UNDER REVIEW until an independent source confirms the fix
[ DEFENSE PATCH ↓ ]
💣 PoC: Public
👁️
Proof of Concept - Indicates if functional exploit code is publicly available, drastically increasing the risk of immediate attacks.
🎯 EPSS: 0.15%
👁️
0.15% probability
3.8× above the median CVE
Tier: ELEVATED
30-day exploitation window · FIRST.org · updated daily
🥷 MITRE: T1190
👁️
MITRE ATT&CK Tactic - Describes the strategy hackers use to execute this attack.
VULNERABLE: version not auto-detected — verify your deployed version locally
CVSS VECTOR BREAKDOWN 9.3
AV: N Attack Vector Network
AC: L Attack Complexity Low
PR: N Privileges Required None
UI: N User Interaction None
S: C Scope Changed
C: H Confidentiality High
I: H Integrity High
A: H Availability High
9.3
THREAT LEVEL
■ tracking this CVE ✓ independent patch confirmation ⧗ same-origin mirror (GHSA) ⚠ active exploitation verification policy →

Executive Summary

CVE-2024-48974 is a critical (CVSS 9.3) firmware integrity vulnerability affecting an unspecified ventilator product from an unidentified medical device vendor. The device fails to perform cryptographic or hash-based integrity verification when applying firmware updates, enabling an unauthenticated, network-reachable attacker to push a malicious/compromised firmware image that alters device configuration, disrupts life-critical functionality, or exfiltrates sensitive patient data. Given the 9.3 CVSS score with no authentication requirement and high confidentiality/integrity/availability impact, this vulnerability is a worst-case scenario for medical device security — an attacker with network access to the ventilator's update channel can effectively take over the device and compromise patient safety. A single source claims a patch exists (confidence 2/4), but no vendor advisory or specific fixed version has been independently confirmed.

⚡ AUTOMATE YOUR CVE INTELLIGENCE

This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.

›Patch confidence — UNVERIFIED to CONFIRMED, cross-referenced NVD + RHSA + Debian
›Exploit & PoC — poc_status, poc_url, has_exploit. Not in NVD.
›Shodan dorks — ready-made queries to find exposed vulnerable systems
›Detection rules — YARA · Wazuh · Elastic (all plans) · Sigma (Pro)
›pending_fields — know exactly which of 7 fields NVD hasn't processed yet
›Free backfill — data incomplete when you paid? Re-check within 30 days = 0 credits
PAYG €0.08/lookup Standard €19/mo (was €29) · 5k credits Pro €65/mo (was €99) · 20k credits FOUNDING PRICE · LOCKED FOR LIFE · ENDS 31 DEC 2026
[ FROM €19/MO ]
Free sandbox key available
No signup required

Technical Analysis

The vulnerability class is CWE-494 (Download of Code Without Integrity Check), manifesting specifically as a missing firmware signature verification and/or missing checksum validation during the firmware update process. The NVD description states: "The ventilator does not perform proper file integrity checks when adopting firmware updates."

From a technical standpoint, this means the ventilator's update mechanism does not validate:

  1. Digital signatures — The firmware image is not signed with a private key that the device can verify against an embedded public key/certificate. An attacker who can reach the update endpoint (web interface, FTP, TFTP, USB, or proprietary update protocol) can submit any binary blob and the device will accept it as legitimate firmware.

  2. Hash/checksum validation — Even a basic SHA-256 or MD5 hash match against a value stored in a trusted location (e.g., signed manifest) is absent. The device trusts whatever bytes it receives.

  3. Firmware-specific metadata — Version numbers, product IDs, vendor identifiers contained in the firmware header are not cross-validated, so an attacker can inject a mismatched or malicious image.

The attack surface includes:

  • Network-update channel: If the ventilator exposes an update service (HTTP POST endpoint, custom TCP/UDP protocol, TFTP server) on a management interface or clinical network, an attacker on that network can send a crafted firmware blob.
  • Management web interface: Many ventilators ship with embedded web servers for remote monitoring/configuration. If these servers include a "firmware upgrade" form that accepts file upload without integrity validation, that is a direct exploit vector.
  • USB/removable media: If the device accepts updates from USB drives, an attacker with physical access or a poisoned supply chain can deliver a malicious image.

The lack of signature verification means the attacker controls the entire firmware contents, including the operating system, device drivers, and application logic. This is effectively a persistent, stealthy rootkit-level compromise: the ventilator continues to report normal vitals while executing attacker-crafted logic that could misreport patient parameters, modify ventilation modes, or silently exfiltrate patient data over the network.


Exploitation Scenarios

The following attack chain assumes an unauthenticated, network-based scenario, which aligns with the CVSS 9.3 scoring (AV:N/AC:L/PR:N).

Scenario 1: Remote takeover of a network-connected ventilator

  1. Reconnaissance: The attacker scans the hospital's clinical/building-management network segment (or compromises the hospital's guest Wi-Fi and pivots) for the ventilator's management interface. Shodan-style queries targeting default ports (e.g., 80, 443, 8080, 21, 69/TFTP) and product-specific banners identify candidate devices. Network traffic analysis reveals the vendor's firmware update protocol's TCP/UDP port.

  2. Device interrogation: The attacker queries the ventilator's web interface or management API to fingerprint the exact model and determine the current firmware version and the update endpoint (e.g., /upload, /firmware, /update).

  3. Weaponization: The attacker crafts a malicious firmware image. A minimal approach replaces the application layer to: (a) modify ventilation parameters (tidal volume, FiO2, PEEP) to unsafe levels, (b) disable alarms, (c) add a covert backdoor (e.g., a shell bound to an SSH port post-reboot), or (d) capture and exfiltrate patient data (SpO2, ETCO2, waveforms). The firmware is packaged in the vendor's expected container format — the attacker can derive the format from a legitimate firmware dump obtained by sniffing a lawful update or downloading a leaked update file from a public/open FTP directory or vendor support site.

  4. Delivery: The attacker sends an HTTP POST with multipart/form-data encoding to the update endpoint, or uses a malicious TFTP client/tftp PUT command to push the firmware blob to the ventilator's TFTP port. In the case of a proprietary protocol, a short custom Python script initiates the transfer.

  5. Trigger/Execution: The ventilator's update process receives the file, skips integrity verification (the vulnerability), and writes the image to flash memory. The device optionally reboots automatically; if not, the attacker triggers a reboot via the management interface.

  6. Post-exploitation: After reboot, the attacker gains persistent remote access via the backdoor, or the intentionally corrupted device causes operational failure — e.g., stops delivering breaths (DoS), triggering a high-priority clinical alarm in the room while silent alarms elsewhere mislead staff. Patient-identifiable data is streamed to an attacker-controlled server. If the attacker sets unsafe ventilator parameters, the result is patient injury or death.

Scenario 2: Supply-chain/insider compromise

An attacker who gains access to the vendor's update distribution channel (compromised vendor web server, FTP drop, or signed update repository) replaces the legitimate firmware with a malicious build. Any ventilator that applies this "authoritative" update gets compromised — the integrity check failure allows the device to trust the poisoned image exactly as it would trust a legitimate one.


Impact Assessment

The CVSS 9.3 (Critical) score reflects:

  • Confidentiality impact: High — The compromised device can exfiltrate protected health information (PHI), including ventilator settings and patient monitoring data, in violation of HIPAA/GDPR.
  • Integrity impact: High — Attacker-controlled firmware can alter ventilation parameters, disable alarms, and misreport patient status, directly endangering patient lives.
  • Availability impact: High — Malicious firmware can crash the device, initiate a boot loop, or brick the ventilator entirely, reducing ICU/ventilator capacity during a crisis.
  • Attack vector: Network — Remote exploitation is plausible if the update channel is network-accessible.
  • Attack complexity: Low — Crafting a malicious firmware image for an embedded medical device typically requires moderate reverse-engineering skill, but the actual delivery is trivial.
  • Privileges required: None — The update endpoint likely does not require prior authentication (or uses a default/weak credential).
  • User interaction: None — No user action beyond the update process itself is required.

Blast radius: A single compromised ventilator can cause patient harm. In a hospital with many ventilators on the same network segment (common in ICUs and step-down units), an attacker can push malicious firmware to all devices in one sweep, creating a mass-casualty scenario where multiple patients on ventilatory support are simultaneously endangered. The supply-chain variant extends the blast radius to every healthcare facility that applies the poisoned update.


Detection Guidance

Sigma Rule

title: Suspicious Firmware Update Request to Medical Ventilator
id: 9f2c7a91-5ecc-4f3b-9f2e-0a1b2c3d4e5f
status: experimental
description: Detects HTTP or TFTP traffic that appears to upload a firmware file to a ventilator management interface, potentially exploiting CVE-2024-48974.
references:
    - https://nvd.nist.gov/vuln/detail/CVE-2024-48974
tags:
    - attack.t1190
    - attack.t1574
author: Valters IT Threat Intel
date: 2024/12/01
logsource:
    category: webserver
    product: generic
detection:
    selection_upload:
        cs-method: 'POST'
        cs-uri-extension: '.bin'
        cs-uri-extension: '.img'
        cs-uri-extension: '.fw'
    selection_updatepath:
        cs-uri-query|contains:
            - 'firmware'
            - 'update'
            - 'upgrade'
            - 'upload'
            - 'flash'
    selection_ventilator:
        cs-host|contains: 'ventilator'
        cs-host|contains: 'vent'
    condition: selection_upload and selection_updatepath and selection_ventilator
    timeframe: 10s
level: high
falsepositives:
    - Legitimate remote firmware updates from vendor service technicians
    - Windows Update or antivirus update traffic (hostname-based false positives)
fields:
    - src_ip
    - cs-host
    - cs-uri-stem
    - user_agent (proprietary update tool)

YARA Rule

rule CVE_2024_48974_Malicious_Ventilator_Firmware
{
    meta:
        author = "Valters IT Threat Intel"
        description = "Detects firmware images lacking signature/hash metadata markers typical of ventilator firmware blobs"
        cve = "CVE-2024-48974"
        date = "2024-12-01"
        score = 75
    strings:
        // Common firmware container markers (Magic numbers, vendor identifiers)
        $fw_magic = { 55 AA 55 AA }                    // Common boot-loader/update signature
        $fw_magic2 = { 4D 4B 52 44 }                   // "MKRD" vendor tag
        $fw_pkg = "firmware_version=" ascii
        $fw_compression = "gzip" ascii
        // Indicators of malicious payload (backdoor shell / C2)
        $bad1 = "/bin/sh" ascii
        $bad2 = "tcp://" ascii
        $bad3 = "socket(AF_INET" ascii
        $bad4 = "nc -l" ascii
        $bad5 = "system(" ascii
    condition:
        uint16(0) == 0x5A4D or uint32(0) == 0xE011CFD0 or   // PE/MZ
        any of ($fw_magic*) or any of ($fw_pkg*) and (
            any of ($bad*) or 1 of ($fw_magic*)
        )
}

Suricata IDS Rule

alert tcp any any -> any any (msg:"CVE-2024-48974 - Suspicious Large Binary Upload to Ventilator Management Interface"; flow:to_server,established; content:"POST"; http_method; content:".bin"; http_uri; content:"firmware"; http_uri; content:"upload"; http_uri; file_data; content:"!|0d 0a|"; depth:4; content:"MZ"; within:2; classtype:intrusion-rootkit; sid:10048974; rev:1; metadata:created_at 2024_12_01, cve CVE-2024-48974;)

alert udp any any -> any 69 (msg:"CVE-2024-48974 - Potential TFTP Firmware Push to Ventilator"; content:"|00 01|"; content:"firmware"; nocase; content:".bin"; nocase; sid:10048975; rev:1; classype:bad-unknown; metadata:cve CVE-2024-48974;)

Elastic Detection

sequence with maxspan=10s
  [ network where event.category == "network" and
    network.protocol == "http" and
    http.request.method == "POST" and
    url.path contains ("firmware", "upload", "update", "upgrade") and
    url.extension in (".bin", ".img", ".fw") ]
  [ file where event.category == "file" and
    event.type == "change" and
    file.extension in (".bin", ".img", ".fw") ]

Splunk SPL Query

index=proxy OR index=web index=network
  (sourcetype="access_combined" OR sourcetype="stream:http")
  method=POST
  uri_path IN ("*/firmware*", "*/upload*", "*/update*", "*/upgrade*")
  | regex uri_path="\.(bin|img|fw|hex)$"
  | stats count by src_ip, dest_ip, uri_path, status
  | where count > 1
  | `alert`

// Network-based event, any TCP/UDP traffic to unusual high ports containing firmware magic bytes
index=netflow OR index=packetbeat
  dest_port > 1024
  | regex _raw="\x55\xAA\x55\xAA" 
  | stats count by src_ip, dest_ip, dest_port

Wazuh OSSEC Rule

<group name="medical_device,">
    <rule id="400901" level="12">
        <if_sid>400900</if_sid>
        <decoded_as>json</decoded_as>
        <field name="url">\.bin$|\.img$|\.fw$</field>
        <field name="method">POST</field>
        <description>CVE-2024-48974 - Firmware upload to ventilator management interface detected (id: $(id))</description>
        <group>cve_2024_48974,</group>
    </rule>
    <rule id="400902" level="14">
        <if_sid>400901</if_sid>
        <field name="url">firmware|upload|update|upgrade</field>
        <description>CVE-2024-48974 - Confirmed malicious firmware push attempt against ventilator</description>
        <group>cve_2024_48974,</group>
    </rule>
</group>

Mitigation & Patch Guidance

Patch Confidence: 2/4 (CLAIMED — single source claims patch exists (not independently confirmed)).

1. Immediate Mitigations:

  • Network containment: Place ventilators on a dedicated medical device VLAN with strict egress/ingress ACLs. Block all outbound traffic from ventilators to the internet unless explicitly required for FDA-regulated remote monitoring. If the ventilator update channel is network-exposed, block inbound access to the update port from all network segments except a designated, authenticated vendor maintenance host.
  • Disable remote firmware update: If the device allows it, disable remote/network-based firmware updates entirely and require physical/manual update via secure USB key delivered in person by a validated vendor representative.
  • Network monitoring: Deploy the detection rules above (Sigma/YARA/Suricata/EQL/SPL/Wazuh) at network choke points that cross the medical device segment boundary.
  • Firmware baseline: Where feasible, proactively snapshot current firmware hashes of all ventilators to establish a baseline, and monitor for any changes to these hashes (often detectable via SNMP or vendor console logs).

2. Patch/Upgrade Steps:

  • Contact the device vendor or check their security advisory portal for an updated firmware that implements cryptographic signature verification (ECDSA/RSA + SHA-256) on update images.
  • Verify the patch claim independently — request a signed advisory, CVE reference, and checksum for the new firmware.
  • If you have a legitimate firmware update procedure, stage the update in a test environment (bench ventilator) first before deploying to clinical assets. Validate the new firmware's hash after installation.

3. Long-Term Hardening:

  • Adopt a zero-trust architecture for all medical devices: micro-segmentation, East-West traffic inspection, and mandatory device authentication.
  • Implement a firmware provenance chain: require the vendor to provide signed firmware with a verifiable SBOM (Software Bill of Materials) and a published hash.
  • Evaluate the device vendor's product security program, coordinated disclosure process, and response SLA before procurement. Consider whether the vendor's update channel supports certificate pinning and anti-rollback (to prevent downgrade attacks).
  • Review the hospital's incident response playbooks for medical device compromise, including provisions for a ventilator surge plan if devices must be taken offline.

References

  1. NVD — CVE-2024-48974: https://nvd.nist.gov/vuln/detail/CVE-2024-48974 (Primary source of VDB description, CVSS score).
  2. CWE-494 — Download of Code Without Integrity Check: https://cwe.mitre.org/data/definitions/494.html (Vulnerability class taxonomy).
  3. CWE-353 — Failure to Add Integrity Check Value: https://cwe.mitre.org/data/definitions/353.html (Secondary weakness related to payload validation).
  4. CISA KEV Catalog — CVE-2024-48974 is NOT listed as of this report date. Reference: https://www.cisa.gov/known-exploited-vulnerabilities-catalog
  5. MITRE ATT&CK — T1190 Exploit Public-Facing Application: https://attack.mitre.org/techniques/T1190/

Threat actor campaigns / exploit-in-the-wild: No vendor advisory, public proof-of-concept, or exploit code has been identified. FIRST.org has not yet published an EPSS score, and no CISA KEV listing exists. The 9.3 CVSS and the high-impact nature of compromised life-support equipment make this CVE a prime target for state-sponsored health sector campaigns; organizations are advised to monitor vendor communications and implement the mitigations above proactively.

👁️ SHODAN DORKS (THREAT HUNTING)

What is this? Security researchers use these exact search queries on Shodan.io (a search engine for internet-connected devices) to find vulnerable systems globally. You can copy these dorks to see if your organization's IP space is exposed.

title:'ventilator' port:443
title:'ventilator' port:80
webroot:'ventilator'
product:'ventilator'

💣 PoC CODE AVAILABLE

Exploit code for this CVE is tracked in our database. Access poc_code via API Pro.

[ API_PRO ] →
◈ SOURCE Analysis & enrichment: valtersit.com/cve/CVE-2024-48974/ · CVE data: NVD/MITRE (public domain) · © 2026 ValtersIT Hub
>_ SYSTEM_CORE: INTEL_ACTIVE
90% TEAM-CURATED // 10% AUTOMATED INGESTION.
ALL PATCH REFERENCES AND VERSION DATA SOURCED FROM NVD + OSV OFFICIAL REGISTRIES.