CVE-2024-9834
Executive Summary
CVE-2024-9834 affects the Baxter Life2000 ventilator due to improper data protection on its serial interface. The flaw permits an attacker with local physical access to send and receive messages, resulting in unauthorized information disclosure and unintended changes to device settings and performance. Enterprise security teams managing medical device fleets face high-severity risks given the CVSS 9.3 score and complete lack of patches.
This record — and 170,000+ others — are available via the ValtersIT API. One endpoint replaces five: NVD + GitHub CVE + CISA KEV + EPSS + Nuclei + Exploit-DB, unified.
No signup required
Technical Analysis
The vulnerability stems from insufficient data protection controls on the ventilator's serial interface, categorized under CWE-200 (Exposure of Sensitive Information to an Unauthorized Actor) or CWE-284 (Improper Access Control). The CNA title and NVD description indicate that the serial port lacks authentication or encryption mechanisms, allowing arbitrary message transmission and reception. No specific function names, endpoints, or code paths are provided in the source data, so analysis remains at the vulnerability class level: unprotected serial communications expose control and telemetry channels. This class of issue typically arises when embedded medical devices expose diagnostic or configuration interfaces without access restrictions, enabling direct interaction with internal settings that affect ventilation parameters, sensor data, or operational state.
Exploitation Scenarios
No public PoC available; attack chain is inferred from vulnerability class.
Steps: 1) Reconnaissance/target identification involves locating Baxter Life2000 ventilators with exposed serial ports in clinical or maintenance environments through physical inspection or facility mapping. 2) The specific flaw class is triggered by establishing a direct serial connection and transmitting messages without any validation or protection checks. 3) Payload/execution method occurs at the vulnerability-class level by issuing arbitrary send/receive commands over the unprotected interface to query or alter device state. 4) Post-exploitation impact includes unauthorized disclosure of patient or device information and unintended modifications to settings and performance parameters, potentially disrupting ventilation delivery.
Impact Assessment
The CVSS 3.1 vector AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H yields a 9.3 score, reflecting full compromise of confidentiality, integrity, and availability from a local, unauthenticated position. Affected systems include any deployed Baxter Life2000 ventilators lacking serial port safeguards. Blast radius extends to clinical environments where altered device performance could impact patient care, while information disclosure may reveal operational or configuration data. With EPSS at 0.00137 and no CISA KEV listing, active exploitation remains low but the unpatched status amplifies long-term risk for healthcare SOC teams.
Detection Guidance
Sigma Rule
title: Baxter Life2000 Serial Interface Access
id: 8f4e2c1a-9b3d-4e7f-a1c2-5d8e9f0a1b2c
status: experimental
description: Detects potential unauthorized serial port access to Baxter Life2000 ventilators
logsource:
product: windows
service: security
detection:
selection:
EventID: 4663
ObjectName|contains: "COM"
ProcessName|contains: "vent"
condition: selection
fields:
- ComputerName
- UserName
level: high
YARA Rule
rule Baxter_Life2000_Serial_Exposure {
meta:
description = "Detects indicators related to unprotected serial access on Baxter Life2000"
author = "valtersit.com"
date = "2024-10"
strings:
$serial = "serial interface" ascii wide
$baxter = "Life2000" ascii wide
condition:
any of them
}
Suricata IDS Rule
alert tcp any any -> any any (msg:"Baxter Life2000 Serial Message Anomaly"; content:"ventilator"; sid:20249834; rev:1;)
Elastic Detection
process where process.name : "serial*" and host.name : "Baxter*"
Splunk SPL Query
index=security EventCode=4663 ObjectName="*COM*"
| search ProcessName="*vent*"
| stats count by ComputerName, UserName
Wazuh OSSEC Rule
<group name="baxter,serial,">
<rule id="100034" level="12">
<if_sid>100002</if_sid>
<match>serial interface</match>
<description>Unauthorized Baxter Life2000 serial access detected</description>
</rule>
</group>
Mitigation & Patch Guidance
Patch confidence: 0/4 (UNPATCHED — no patch evidence from any tracked source).
- Immediate mitigations include physically securing serial ports with port blockers or locks and restricting physical access to ventilator units in clinical areas. 2) Patch/upgrade steps are unavailable as no vendor fix or affected version list exists. 3) Long-term hardening requires network segmentation of medical devices, implementation of serial interface authentication where hardware permits, and continuous inventory monitoring for Baxter Life2000 units.
References
https://nvd.nist.gov/vuln/detail/CVE-2024-9834
https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2024-9834
Baxter medical device security documentation (no specific advisory issued)
No known threat actor campaigns or exploit-in-the-wild evidence recorded.
What is this? Security researchers use these exact search queries on Shodan.io (a search engine for internet-connected devices) to find vulnerable systems globally. You can copy these dorks to see if your organization's IP space is exposed.